Literature DB >> 16034227

Transcutaneous electrical nerve stimulation versus baclofen in spasticity: clinical and electrophysiologic comparison.

Gülümser Aydin1, Serap Tomruk, Işik Keleş, Sibel Ozbudak Demir, Sevim Orkun.   

Abstract

OBJECTIVES: Clinical and electrophysiologic comparison of the efficacy of transcutaneous electrical nerve stimulation (TENS) and oral baclofen in the treatment of spasticity.
DESIGN: Patients with spinal cord injury and spasticity were included in the study. Ten patients were assigned to oral baclofen and 11 to TENS groups. For the comparison of H-reflex variables, 20 healthy individuals were allocated to a control group. TENS was applied to the tibial nerve for 15 days at a frequency of 100 Hz. Clinical (spasm frequency scale, painful spasm scale, lower limb Ashworth score, clonus score, deep tendon reflex score, plantar stimulation response score) and electrophysiologic evaluations (H-reflex response at the highest amplitude, latency of maximum H-reflex, and ratio of H-reflex response at the highest amplitude to M response at maximum amplitude) of the lower limb and functional evaluations (functional disability score and FIM) were carried out in baclofen and TENS groups before and after treatment. Posttreatment evaluation was made 24 hrs after the 15th session in the TENS group. In addition, clinical spasticity scores and electrophysiologic variables were measured 15 mins after the first application and 15 mins after the 15th session.
RESULTS: Significant improvement was detected in lower limb Ashworth score, spasm frequency scale, deep tendon reflex score, functional disability score, and FIM in the baclofen (P = 0.011, P = 0.014, P = 0.025, P = 0.004, and P = 0.005, respectively) and TENS (P = 0.020, P = 0.014, P = 0.025, P = 0.003, and P = 0.003, respectively) group after treatment. Decrease in H-reflex maximum amplitude was significant in the TENS group (P = 0.026). Most marked improvement was observed in the third evaluation, 15 mins after the 15th session, particularly in lower limb Ashworth score (P = 0.006) and H-reflex maximum amplitude (P = 0.006) in the TENS group. The percentage change in clinical, electrophysiologic, and functional variables caused by baclofen was not different from that caused by repeated applications of TENS in the short- and long-term evaluations (P > 0.05).
CONCLUSION: TENS may be recommended as a supplement to medical treatment in the management of spasticity.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16034227     DOI: 10.1097/01.phm.0000171173.86312.69

Source DB:  PubMed          Journal:  Am J Phys Med Rehabil        ISSN: 0894-9115            Impact factor:   2.159


  19 in total

1.  Selective effects of baclofen on use-dependent modulation of GABAB inhibition after tetraplegia.

Authors:  Melissa D Barry; Karen L Bunday; Robert Chen; Monica A Perez
Journal:  J Neurosci       Date:  2013-07-31       Impact factor: 6.167

2.  Imbalanced Corticospinal and Reticulospinal Contributions to Spasticity in Humans with Spinal Cord Injury.

Authors:  Sina Sangari; Monica A Perez
Journal:  J Neurosci       Date:  2019-08-14       Impact factor: 6.167

3.  Cutaneous inputs from the back abolish locomotor-like activity and reduce spastic-like activity in the adult cat following complete spinal cord injury.

Authors:  Alain Frigon; Yann Thibaudier; Michael D Johnson; C J Heckman; Marie-France Hurteau
Journal:  Exp Neurol       Date:  2012-04-01       Impact factor: 5.330

4.  Spinal Cord Injury Provoked Neuropathic Pain and Spasticity, and Their GABAergic Connection.

Authors:  Ankita Bhagwani; Manjeet Chopra; Hemant Kumar
Journal:  Neurospine       Date:  2022-09-30

Review 5.  Characterising the Features of 381 Clinical Studies Evaluating Transcutaneous Electrical Nerve Stimulation (TENS) for Pain Relief: A Secondary Analysis of the Meta-TENS Study to Improve Future Research.

Authors:  Mark I Johnson; Carole A Paley; Priscilla G Wittkopf; Matthew R Mulvey; Gareth Jones
Journal:  Medicina (Kaunas)       Date:  2022-06-14       Impact factor: 2.948

6.  Comparison of transcutaneous electrical nerve stimulation (TENS) and functional electrical stimulation (FES) for spasticity in spinal cord injury - A pilot randomized cross-over trial.

Authors:  Anjali Sivaramakrishnan; John M Solomon; Natarajan Manikandan
Journal:  J Spinal Cord Med       Date:  2017-10-25       Impact factor: 1.985

Review 7.  Recovery of neuronal and network excitability after spinal cord injury and implications for spasticity.

Authors:  Jessica M D'Amico; Elizabeth G Condliffe; Karen J B Martins; David J Bennett; Monica A Gorassini
Journal:  Front Integr Neurosci       Date:  2014-05-12

8.  Management of spasticity with severe painful myoclonic jerks in an operated case of spinal astrocytoma.

Authors:  Pradeep Jain; Murali Krishna Chava
Journal:  Indian J Anaesth       Date:  2014 Nov-Dec

9.  Efficacy and safety of transcutaneous electrical acupoint stimulation to treat muscle spasticity following brain injury: a double-blinded, multicenter, randomized controlled trial.

Authors:  Wenli Zhao; Chao Wang; Zhongzheng Li; Lei Chen; Jianbo Li; Weidong Cui; Shasha Ding; Qiang Xi; Fan Wang; Fei Jia; Shuhua Xiao; Yi Guo; Ye Zhao
Journal:  PLoS One       Date:  2015-02-02       Impact factor: 3.240

Review 10.  Induction of central nervous system plasticity by repetitive transcranial magnetic stimulation to promote sensorimotor recovery in incomplete spinal cord injury.

Authors:  Peter H Ellaway; Natalia Vásquez; Michael Craggs
Journal:  Front Integr Neurosci       Date:  2014-05-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.