Literature DB >> 16032674

Efficiency of inversion pulses for background suppressed arterial spin labeling.

Dairon M Garcia1, Guillaume Duhamel, David C Alsop.   

Abstract

Background suppression strategies for arterial spin labeling (ASL) MRI offer reduced noise from motion and other system instabilities. However, the inversion pulses used for suppression can also attenuate the ASL signal, which may offset the advantages of background suppression. Numerical simulations were used to optimize the inversion efficiency of four candidate pulses over a range of radiofrequency (RF) and static magnetic field variations typical of in vivo imaging. Optimized pulses were then used within a pulsed ASL sequence to assess the pulses' in vivo inversion efficiencies for ASL. The measured in vivo inversion efficiency was significantly lower than theoretical predictions (e.g., 93% experimental compared to 99% theoretical) for the tangent hyperbolic pulse applied in a background suppression scheme. This inefficiency was supported by an in vitro study of human blood. These results suggest that slow magnetization transfer (MT) in blood, either with bound water or macromolecular protons, dominates the inversion inefficiency in blood. Despite the attenuated signal relative to unsuppressed ASL, the signal-to-noise ratio (SNR) with suppression was improved by 23-110% depending on the size of the region measured. Knowledge of efficiency will aid optimization of the number of suppression pulses and provide more accurate quantification of blood flow. 2005 Wiley-Liss, Inc

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16032674     DOI: 10.1002/mrm.20556

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  109 in total

1.  Whole-brain cerebral blood flow mapping using 3D echo planar imaging and pulsed arterial tagging.

Authors:  Neville D Gai; S Lalith Talagala; John A Butman
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  CBF measurements using multidelay pseudocontinuous and velocity-selective arterial spin labeling in patients with long arterial transit delays: comparison with xenon CT CBF.

Authors:  Deqiang Qiu; Matus Straka; Zungho Zun; Roland Bammer; Michael E Moseley; Greg Zaharchuk
Journal:  J Magn Reson Imaging       Date:  2012-02-22       Impact factor: 4.813

3.  Blood flow MRI of the human retina/choroid during rest and isometric exercise.

Authors:  Yi Zhang; Oscar San Emeterio Nateras; Qi Peng; Carlos A Rosende; Timothy Q Duong
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-06-28       Impact factor: 4.799

4.  Cerebral blood flow in posterior cortical nodes of the default mode network decreases with task engagement but remains higher than in most brain regions.

Authors:  Adolf Pfefferbaum; Sandra Chanraud; Anne-Lise Pitel; Eva Müller-Oehring; Ajit Shankaranarayanan; David C Alsop; Torsten Rohlfing; Edith V Sullivan
Journal:  Cereb Cortex       Date:  2010-05-19       Impact factor: 5.357

5.  A Short Introduction to Arterial Spin Labeling and its Application to Flow Territory Mapping.

Authors:  T Lindner; M Helle; O Jansen
Journal:  Clin Neuroradiol       Date:  2015-08-26       Impact factor: 3.649

6.  A novel joint sparse partial correlation method for estimating group functional networks.

Authors:  Xiaoyun Liang; Alan Connelly; Fernando Calamante
Journal:  Hum Brain Mapp       Date:  2015-12-21       Impact factor: 5.038

7.  Accuracy of Parenchymal Cerebral Blood Flow Measurements Using Pseudocontinuous Arterial Spin-Labeling in Healthy Volunteers.

Authors:  K Ambarki; A Wåhlin; L Zarrinkoob; R Wirestam; J Petr; J Malm; A Eklund
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-06       Impact factor: 3.825

8.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

9.  The stronger one-sided relative hypoperfusion, the more pronounced ipsilateral spatial attentional bias in patients with asymptomatic carotid stenosis.

Authors:  Jens Göttler; Stephan Kaczmarz; Rachel Nuttall; Vanessa Griese; Natan Napiórkowski; Michael Kallmayer; Isabel Wustrow; Hans-Henning Eckstein; Claus Zimmer; Christine Preibisch; Kathrin Finke; Christian Sorg
Journal:  J Cereb Blood Flow Metab       Date:  2018-11-27       Impact factor: 6.200

10.  Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease.

Authors:  Guofan Xu; Howard A Rowley; Gaohong Wu; David C Alsop; Ajit Shankaranarayanan; Maritza Dowling; Bradley T Christian; Terrence R Oakes; Sterling C Johnson
Journal:  NMR Biomed       Date:  2010-04       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.