Literature DB >> 16030318

The use of a hybrid linear trap/FT-ICR mass spectrometer for on-line high resolution/high mass accuracy bottom-up sequencing.

Scott M Peterman1, Craig P Dufresne, Stevan Horning.   

Abstract

In this work we present a hybrid linear trap/Fourier transform ion cyclotron resonance (ICR) mass spectrometer to perform protein sequencing using the bottom-up approach. We demonstrate that incorporation of the linear trap greatly enhances the overall performance of the hybrid system for the study of complex peptide mixtures separated by fast high-performance liquid chromatography gradients. The ability to detect in the linear trap enables employment of automatic gain control to greatly reduce space charging in the ICR cell irregardless of ion flux. Resulting accurate mass measurements of 2 ppm or better using external calibration are achieved for the base peak as well as ions at 2% relative abundance. The linear trap is used to perform ion accumulation and activation prior to detection in the ICR cell which increases the scan rate. The increased duty cycle allows for data-dependent mass analysis of coeluting peptides to be acquired increasing protein sequence coverage without increasing the gradient length. In addition, the linear trap could be used as an ion detection device to perform simultaneous detection of tandem mass spectra with full scan mass spectral detection in the ICR cell resulting in the fastest scan cycles for performing bottom-up sequencing of protein digests. Comparisons of protein sequence coverage are presented for product ion detection in the linear trap and ICR cell.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16030318      PMCID: PMC2291714     

Source DB:  PubMed          Journal:  J Biomol Tech        ISSN: 1524-0215


  15 in total

1.  Infrared multiphoton dissociation in an external ion reservoir.

Authors:  S A Hofstadler; K A Sannes-Lowery; R H Griffey
Journal:  Anal Chem       Date:  1999-06-01       Impact factor: 6.986

2.  Accurate mass multiplexed tandem mass spectrometry for high-throughput polypeptide identification from mixtures.

Authors:  C Masselon; G A Anderson; R Harkewicz; J E Bruce; L Pasa-Tolic; R D Smith
Journal:  Anal Chem       Date:  2000-04-15       Impact factor: 6.986

3.  Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer.

Authors:  M E Belov; E N Nikolaev; G A Anderson; H R Udseth; T P Conrads; T D Veenstra; C D Masselon; M V Gorshkov; R D Smith
Journal:  Anal Chem       Date:  2001-01-15       Impact factor: 6.986

Review 4.  Mass spectrometry in proteomics.

Authors:  R Aebersold; D R Goodlett
Journal:  Chem Rev       Date:  2001-02       Impact factor: 60.622

5.  Factors that affect ion trap data-dependent MS/MS in proteomics.

Authors:  Brett R Wenner; Bert C Lynn
Journal:  J Am Soc Mass Spectrom       Date:  2004-02       Impact factor: 3.109

6.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

7.  Improved fourier-transform ion-cyclotron-resonance mass spectrometry of large biomolecules.

Authors:  S C Beu; M W Senko; J P Quinn; F W McLafferty
Journal:  J Am Soc Mass Spectrom       Date:  1993-02       Impact factor: 3.109

8.  Multipole storage assisted dissociation, a novel in-source dissociation technique for electrospray ionization generated ions.

Authors:  K Sannes-Lowery; R H Griffey; G H Kruppa; J P Speir; S A Hofstadler
Journal:  Rapid Commun Mass Spectrom       Date:  1998       Impact factor: 2.419

9.  Direct analysis of protein complexes using mass spectrometry.

Authors:  A J Link; J Eng; D M Schieltz; E Carmack; G J Mize; D R Morris; B M Garvik; J R Yates
Journal:  Nat Biotechnol       Date:  1999-07       Impact factor: 54.908

10.  High sensitivity Fourier transform ion cyclotron resonance mass spectrometry for biological analysis with nano-LC and microelectrospray ionization.

Authors:  T L Quenzer; M R Emmett; C L Hendrickson; P H Kelly; A G Marshall
Journal:  Anal Chem       Date:  2001-04-15       Impact factor: 6.986

View more
  13 in total

1.  CrossSearch, a user-friendly search engine for detecting chemically cross-linked peptides in conjugated proteins.

Authors:  Owen W Nadeau; Gerald J Wyckoff; Justin E Paschall; Antonio Artigues; Jessica Sage; Maria T Villar; Gerald M Carlson
Journal:  Mol Cell Proteomics       Date:  2008-02-16       Impact factor: 5.911

2.  Automated online sequential isotope labeling for protein quantitation applied to proteasome tissue-specific diversity.

Authors:  Reinout Raijmakers; Celia R Berkers; Annemieke de Jong; Huib Ovaa; Albert J R Heck; Shabaz Mohammed
Journal:  Mol Cell Proteomics       Date:  2008-06-04       Impact factor: 5.911

3.  Identification of protein-protein interactions and topologies in living cells with chemical cross-linking and mass spectrometry.

Authors:  Haizhen Zhang; Xiaoting Tang; Gerhard R Munske; Nikola Tolic; Gordon A Anderson; James E Bruce
Journal:  Mol Cell Proteomics       Date:  2008-10-20       Impact factor: 5.911

4.  Predicting protein post-translational modifications using meta-analysis of proteome scale data sets.

Authors:  Daniel Schwartz; Michael F Chou; George M Church
Journal:  Mol Cell Proteomics       Date:  2008-10-28       Impact factor: 5.911

5.  High Mass Ion Detection with Charge Detector Coupled to Rectilinear Ion Trap Mass Spectrometer.

Authors:  Avinash A Patil; Szu-Wei Chou; Pei-Yu Chang; Chen-Wei Lee; Chun-Yen Cheng; Ming-Lee Chu; Wen-Ping Peng
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-13       Impact factor: 3.109

6.  Multisite phosphorylation of voltage-gated sodium channel alpha subunits from rat brain.

Authors:  Frank J Berendt; Kang-Sik Park; James S Trimmer
Journal:  J Proteome Res       Date:  2010-04-05       Impact factor: 4.466

7.  Can museum egg specimens be used for proteomic analyses?

Authors:  Steven J Portugal; Helen J Cooper; Cleidiane G Zampronio; Laine L Wallace; Phillip Cassey
Journal:  Proteome Sci       Date:  2010-07-14       Impact factor: 2.480

8.  Comparison of database search strategies for high precursor mass accuracy MS/MS data.

Authors:  Edward J Hsieh; Michael R Hoopmann; Brendan MacLean; Michael J MacCoss
Journal:  J Proteome Res       Date:  2010-02-05       Impact factor: 4.466

9.  Precursor-ion mass re-estimation improves peptide identification on hybrid instruments.

Authors:  Roland Luethy; Darren E Kessner; Jonathan E Katz; Brendan Maclean; Robert Grothe; Kian Kani; Vitor Faça; Sharon Pitteri; Samir Hanash; David B Agus; Parag Mallick
Journal:  J Proteome Res       Date:  2008-08-16       Impact factor: 4.466

10.  The Human Scavenger Receptor CD36: glycosylation status and its role in trafficking and function.

Authors:  Sarah J Hoosdally; Edward J Andress; Carol Wooding; Catherine A Martin; Kenneth J Linton
Journal:  J Biol Chem       Date:  2009-04-15       Impact factor: 5.157

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.