Literature DB >> 16027938

Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes.

Oliver Hofmann1, Xuhua Wang, John C Demello, Donal D C Bradley, Andrew J Demello.   

Abstract

As a first step towards a fully disposable stand-alone diagnostic microchip for determination of urinary human serum albumin (HSA), we report the use of a thin-film organic light emitting diode (OLED) as an excitation source for microscale fluorescence detection. The OLED has a peak emission wavelength of 540 nm, is simple to fabricate on flexible or rigid substrates, and operates at drive voltages below 10 V. In a fluorescence assay, HSA is reacted with Albumin Blue 580, generating a strong emission at 620 nm when excited with the OLED. Filter-less discrimination between excitation light and generated fluorescence is achieved through an orthogonal detection geometry. When the assay is performed in 800 microm deep and 800 microm wide microchannels on a poly(dimethylsiloxane)(PDMS) microchip at flow rates of 20 microL min(-1), HSA concentrations down to 10 mg L(-1) can be detected with a linear range from 10 to 100 mg L(-1). This sensitivity is sufficient for the determination of microalbuminuria (MAU), an increased urinary albumin excretion indicative of renal disease (clinical cut-off levels: 15-40 mg L(-1)).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16027938     DOI: 10.1039/b504551g

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  5 in total

1.  Albumin testing in urine using a smart-phone.

Authors:  Ahmet F Coskun; Richie Nagi; Kayvon Sadeghi; Stephen Phillips; Aydogan Ozcan
Journal:  Lab Chip       Date:  2013-11-07       Impact factor: 6.799

Review 2.  Sacrificial layer microfluidic device fabrication methods.

Authors:  Bridget A Peeni; Milton L Lee; Aaron R Hawkins; Adam T Woolley
Journal:  Electrophoresis       Date:  2006-12       Impact factor: 3.535

Review 3.  On-chip biomedical imaging.

Authors:  Zoltán Göröcs; Aydogan Ozcan
Journal:  IEEE Rev Biomed Eng       Date:  2013

4.  A Compact Detection Platform Based on Gradient Guided-Mode Resonance for Colorimetric and Fluorescence Liquid Assay Detection.

Authors:  Jing-Jhong Gao; Ching-Wei Chiu; Kuo-Hsing Wen; Cheng-Sheng Huang
Journal:  Sensors (Basel)       Date:  2021-04-15       Impact factor: 3.576

Review 5.  The Current State of Optical Sensors in Medical Wearables.

Authors:  Erik Vavrinsky; Niloofar Ebrahimzadeh Esfahani; Michal Hausner; Anton Kuzma; Vratislav Rezo; Martin Donoval; Helena Kosnacova
Journal:  Biosensors (Basel)       Date:  2022-04-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.