Literature DB >> 16027627

Unequal outer and inner bow configurations: comparing 2 asymmetric headgear systems.

Tamar Brosh1, Schay Portal, Ofer Sarne, Alexander D Vardimon.   

Abstract

INTRODUCTION: Asymmetric headgear is used when different molar distalization forces (MDF) are needed on the right and left sides of the jaw to correct a Class II molar relationship.
METHODS: We investigated 2 asymmetric headgear configurations, the outer-bow and the inner-bow, on cervical-pull headgear. In the first configuration, 5 hooks were soldered on 1 side of the outer bow at 10-mm intervals, making this side shorter; in the other, 4 stops (1.5 mm) were added to 1 side of the inner bow, making this side longer. The right and left MDF and the extraoral force (EF) were measured simultaneously with 2 fork transducers and a testing machine, respectively.
RESULTS: A 40-mm difference between the long and short outer bows resulted in a 2.17-fold greater MDF on the long-side molar (7:3 ratio). The 3-4 stop configuration provided the optimal inner-bow arrangement, with stop/no-stop MDF ratios of 7:3 and 10:0, respectively, at 10 N EF. At low-to-medium EF levels, a unilateral MDF developed on the stop side with zero MDF on the no-stop side. The sum of the right and left MDF nearly equaled the EF in the outer-bow asymmetry and was 60% in the inner-bow setting; this suggests strong lateral forces in the latter.
CONCLUSIONS: Clinically, for a bilateral unequal Class II relationship, the system of choice is outer-bow asymmetric headgear. For a unilateral Class II relationship with 1 side in a Class I molar relationship (Class II subdivision), inner-bow asymmetric headgear is recommended.

Mesh:

Year:  2005        PMID: 16027627     DOI: 10.1016/j.ajodo.2004.07.040

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Comparison of two asymmetric headgear force systems: A finite element analysis.

Authors:  Samaneh Sadeghi; Zohreh Hedayati; Batoolalsadat Mousavi-Fard
Journal:  Dental Press J Orthod       Date:  2019-05-20

2.  Biomechanical reevaluation of orthodontic asymmetric headgear.

Authors:  Lu Chi; Mulin Cheng; H Garland Hershey; Tung Nguyen; Ching-Chang Ko
Journal:  Angle Orthod       Date:  2011-12-08       Impact factor: 2.079

3.  Unilateral Outer Bow Expanded Cervical Headgear Force System: 3D Analysis Using Finite Element Method.

Authors:  Allahyar Geramy; Omid Mortezai; Masomeh Esmaily; Hojat Darvishpour
Journal:  J Dent (Tehran)       Date:  2015-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.