Literature DB >> 16025466

Enhanced fixation of implants by bone ingrowth to titanium fiber mesh: effect of incorporation of hydroxyapatite powder.

Tadashi Tsukeoka1, Masahiko Suzuki, Chikara Ohtsuki, Yoshikazu Tsuneizumi, Jin Miyagi, Atsushi Sugino, Takayuki Inoue, Ryouichi Michihiro, Hideshige Moriya.   

Abstract

Tight fixation between bone and implant materials is of great importance for a successful outcome of procedures such as total knee arthroplasty (TKA) and total hip arthroplasty (THA). Titanium fiber mesh is an attractive structure for the establishment of tight fixation between bone and implant by bone ingrowth into the spaces among the fibers. Enhancement of bone ingrowth is desired not only for tight fixation but also for a fast recovery. Our hypothesis is that just the presence of hydroxyapatite (HA) particles ensures improved bone ingrowth, and that long-term stability can be obtained by mechanical anchoring of bone in the spaces among titanium fibers. In this study, we examine our hypothesis by in vivo experiment using dog femur. HA particles were incorporated in titanium fiber mesh coated on titanium alloy rod by dipping in a slurry of HA with hydroxy-propyl-cellulose in an ethanol solution. Specimens were implanted for 3, 5, and 8 weeks, and were then compared with the results from specimens without the use of HA. Bonding strength was evaluated by push-out test, and histomorphometric measurements were made with analysis software to calculate the average value of bone ingrowth. A significantly higher bonding strength was observed for the specimens with HA-incorporated implant at 3 and 5 weeks, and larger bone ingrowth deep inside the titanium fiber mesh was measured at 3 weeks. Our proposed method has the additional advantage of not requiring a high temperature that may result in changes in characters of HA powder such as phase transition, grain growth, and decomposition. Moreover, this technique of HA powder incorporation without high-temperature treatment allows the use of several types of metallic fiber mesh, as well as the application to fiber mesh made of organic polymers. We conclude that this simple modification of titanium fiber mesh with HA powder can improve the fixation of implant to bone in the initial stage after operation. (c) 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16025466     DOI: 10.1002/jbm.b.30282

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  7 in total

1.  Osteogenic protein-1 delivered by hydroxyapatite-coated implants improves bone ingrowth in extracortical bone bridging.

Authors:  Neil Saran; Renwen Zhang; Robert E Turcotte
Journal:  Clin Orthop Relat Res       Date:  2010-09-28       Impact factor: 4.176

2.  Bone ingrowth potential of electron beam and selective laser melting produced trabecular-like implant surfaces with and without a biomimetic coating.

Authors:  J E Biemond; G Hannink; N Verdonschot; P Buma
Journal:  J Mater Sci Mater Med       Date:  2012-12-21       Impact factor: 3.896

3.  Micro-computed tomography analysis of early stage bone healing using micro-porous titanium mesh for guided bone regeneration: preliminary experiment in a canine model.

Authors:  Yunia Dwi Rakhmatia; Yasunori Ayukawa; Yohei Jinno; Akihiro Furuhashi; Kiyoshi Koyano
Journal:  Odontology       Date:  2017-04-07       Impact factor: 2.634

4.  Effect of thin carbonate-containing apatite (CA) coating of titanium fiber mesh on trabecular bone response.

Authors:  Tohru Hayakawa; Kenichi Takahashi; Hiroyuki Okada; Masao Yoshinari; Hiroki Hara; Chihiro Mochizuki; Hirotsugu Yamamoto; Mitsunobu Sato
Journal:  J Mater Sci Mater Med       Date:  2007-10-30       Impact factor: 3.896

5.  Assessment of bone ingrowth potential of biomimetic hydroxyapatite and brushite coated porous E-beam structures.

Authors:  J Elizabeth Biemond; Tatiane S Eufrásio; Gerjon Hannink; Nico Verdonschot; Pieter Buma
Journal:  J Mater Sci Mater Med       Date:  2011-02-16       Impact factor: 3.896

6.  A comparative study of flat surface design and medial pivot design in posterior cruciate-retaining total knee arthroplasty: a matched pair cohort study of two years.

Authors:  Junichi Nakamura; Takaki Inoue; Toru Suguro; Masahiko Suzuki; Takahisa Sasho; Shigeo Hagiwara; Ryuichiro Akagi; Sumihisa Orita; Kazuhide Inage; Tsutomu Akazawa; Seiji Ohtori
Journal:  BMC Musculoskelet Disord       Date:  2018-07-18       Impact factor: 2.362

7.  Biologic response to carbonated hydroxyapatite associated with orthopedic device: experimental study in a rabbit model.

Authors:  Samira Jebahi; Mongi Saoudi; Riadh Badraoui; Tarek Rebai; Hassane Oudadesse; Zoubaier Ellouz; Hassib Keskese; Abdelfattah El Feki; Hafed El Feki
Journal:  Korean J Pathol       Date:  2012-02-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.