Literature DB >> 16025090

Measurement of total and differential white blood cell counts in synovial fluid by means of an automated hematology analyzer.

Hiroyuki Sugiuchi1, Yukio Ando, Masahiro Manabe, Eiichi Nakamura, Hiroshi Mizuta, Shiro Nagata, Hiroaki Okabe.   

Abstract

We developed a rapid and accurate method for quantifying total and differential white blood cell (WBC) counts by pretreating synovial fluid with hyaluronidase and using an automated hematology analyzer. Forty-seven samples of synovial fluid that had been placed in blood-collection tubes containing ethylenediamine- N,N,N',N' -tetraacetic acid as an anticoagulant were treated with hyaluronidase at 37 degrees C for 10 minutes, and then the total and differential WBC counts were determined by means of the automated hematology analyzer. Results were compared with those achieved by traditional manual counting methods. For the automated method, the coefficient of variation values for within-run precision of the WBC count were 5.27%, 3.56%, and 3.01% at 0.54, 1.12, and 2.05 x 10(9) /L, respectively; the run-to-run coefficient of variation values was less than 10.0%. The total and differential WBC counts obtained by this automated method showed good correlation with those obtained by the hemocytometer method ( r = .998; P < .0001; regression formula, y = 0.986 x - 0.072). Bland-Altman plots indicated no significant discrepancy between the methods. Our evaluation supports the use of this automated hematology analyzer method to measure total and differential WBC counts, which should aid clinical diagnosis.

Mesh:

Year:  2005        PMID: 16025090     DOI: 10.1016/j.lab.2005.04.004

Source DB:  PubMed          Journal:  J Lab Clin Med        ISSN: 0022-2143


  3 in total

1.  Semi-quantitative monitoring of confluence of adherent mesenchymal stromal cells on calcium-phosphate granules by using widefield microscopy images.

Authors:  Filippo Piccinini; Michela Pierini; Enrico Lucarelli; Alessandro Bevilacqua
Journal:  J Mater Sci Mater Med       Date:  2014-05-28       Impact factor: 3.896

2.  The effect of robenacoxib on the concentration of C-reactive protein in synovial fluid from dogs with osteoarthritis.

Authors:  David Bennett; Peter David Eckersall; Mary Waterston; Veronica Marchetti; Alessandra Rota; Eilidh McCulloch; Silvia Sbrana
Journal:  BMC Vet Res       Date:  2013-03-01       Impact factor: 2.741

3.  The Graphical Representation of Cell Count Representation: A New Procedure for the Diagnosis of Periprosthetic Joint Infections.

Authors:  Bernd Fink; Marius Hoyka; Elke Weissbarth; Philipp Schuster; Irina Berger
Journal:  Antibiotics (Basel)       Date:  2021-03-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.