Literature DB >> 16023774

Structural characteristics of impaction allografting for revision total hip arthroplasty.

Marcus C Robinson1, Göran Fernlund, R M Dominic Meek, Bassam A Masri, Clive P Duncan, Thomas R Oxland.   

Abstract

BACKGROUND: The impaction allografting procedure for treatment of failed hip reconstructions has shown promising but variable results. The objective of this study was to compare the structural characteristics of revision total hip arthroplasty constructs with impaction allografting (cement+morsellized bone) with all-cement and all-morsellized bone constructs.
METHODS: Uniaxial cyclic compression was applied to a simplified uniaxial, parallel, aluminum tube model to simulate normal gait. Applied force and axial stem displacement were recorded to determine stem subsidence and construct stiffness.
FINDINGS: Introduction of a small amount of cement into the bone graft, as suggested in an impaction allografting procedure previously reported, makes the construct behave structurally more similar to an all-cemented construct than to an all-bone graft construct.
INTERPRETATION: The results suggest that the structural properties achieved in an impaction allografting construct are sensitive to the amount of cement in the graft and that care should be taken clinically to achieve consistent constructs.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16023774     DOI: 10.1016/j.clinbiomech.2005.05.013

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

Review 1.  [Influence of thermodisinfection on impaction of cancellous bone : An in vitro model of femoral impaction bone grafting].

Authors:  C Fölsch; A Jahnke; A Groß; G Martels; G A Krombach; M Rickert; M Kampschulte
Journal:  Orthopade       Date:  2018-01       Impact factor: 1.087

Review 2.  [Allogeneic bone transplantation in hip revision surgery : Indications and potential for reconstruction].

Authors:  G A Ahmed; B Ishaque; M Rickert; C Fölsch
Journal:  Orthopade       Date:  2018-01       Impact factor: 1.087

3.  Influence of antibiotic pellets on pore size and shear stress resistance of impacted native and thermodisinfected cancellous bone: An in vitro femoral impaction bone grafting model.

Authors:  C Fölsch; J Bok; G A Krombach; M Rickert; C A Fonseca Ulloa; G A Ahmed; M Kampschulte; A Jahnke
Journal:  J Orthop       Date:  2020-09-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.