Literature DB >> 1602334

Factors influencing postoperative movement in displaced femoral neck fractures: evaluation by conventional radiography and stereoradiography.

J I Ragnarsson1, J Kärrholm.   

Abstract

Postoperative movement in 46 displaced femoral neck fractures was studied using roentgen stereophotogrammetric analysis (RSA). Thirty-four fractures became stable, all within 1 year. Measurements on pre- and postreduction radiographs and scintimetry were performed to evaluate factors of importance in healing, redisplacement, and nonunion. Thirty-three fractures were treated with two hook-pins with (7 cases) or without (26 cases) a plate, and 13 were treated with two cancellous screws. Presence of intermediate fracture fragments and fixation with two screws implied increased movement of the femoral head center during the postoperative period. Remaining ad latus displacement on the anteroposterior or lateral view after reduction of more than 1 mm and low scintimetric uptake implied increased risk of redisplacement or pseudarthrosis. Increased displacement of the femoral head center during the first postoperative month was recorded in fractures that did not heal. The magnitude of the femoral head rotations did not differ between the implants, but smaller screw axis rotations were noted in fractures that subsequently healed. In most hips fixated with screws, the instant center of femoral head rotation went through the femoral head or neck, whereas hook-pin fixation more commonly was associated with screw axis position within or close to the trochanteric region, suggesting a more durable fixation in the femoral head of this device.

Entities:  

Mesh:

Year:  1992        PMID: 1602334     DOI: 10.1097/00005131-199206000-00004

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  4 in total

1.  Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture.

Authors:  Zheng Wang; Yong Yang; Gangning Feng; Haohui Guo; Zhirong Chen; Yaogeng Chen; Qunhua Jin
Journal:  Biomed Eng Online       Date:  2022-06-10       Impact factor: 3.903

2.  Differentially loaded radiostereometric analysis to monitor fracture stiffness: a feasibility study.

Authors:  Mellick J Chehade; Lucian B Solomon; Stuart A Callary; Sam H Benveniste; Anthony P Pohl; Donald W Howie
Journal:  Clin Orthop Relat Res       Date:  2009-01-29       Impact factor: 4.176

3.  Similar outcome of femoral neck fractures treated with Pinloc or Hansson Pins: 1-year data from a multicenter randomized clinical study on 439 patients.

Authors:  Kristine Kalland; Henrik Åberg; Anna Berggren; Michael Ullman; Greta Snellman; Kenneth B Jonsson; Torsten Johansson
Journal:  Acta Orthop       Date:  2019-08-27       Impact factor: 3.717

4.  Radiostereometric analysis of the initial stability of internally fixed femoral neck fractures under differential loading.

Authors:  Sami Finnilä; Niko Moritz; Niko Strandberg; Jessica J Alm; Hannu T Aro
Journal:  J Orthop Res       Date:  2018-10-25       Impact factor: 3.494

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.