M Johansen1, F Tønnesen, K E Rasmussen.
Abstract
A sensitive and selective method for the detection of pholcodine and its metabolite morphine in urine using high-performance liquid chromatography is described. It involves on-line clean-up of urine on a trace enrichment column packed with a polymeric strong cation-exchange material. Pholcodine and its metabolites were separated on two analytical columns with different selectivities. Pholcodine was detected by a fluorescence detector and morphine was detected electrochemically. One system, based on reversed-phase chromatography, applied a polystyrene-divinylbenzene column and gradient elution. The other system was based on normal-phase chromatography with a silica column and isocratic elution. Morphine was confirmed to be a metabolite of pholcodine by reversed-phase chromatography and electrochemical detection. Two unidentified metabolites of pholcodine were separated from pholcodine by normal-phase chromatography and detected by fluorescence detection.Entities: