| Literature DB >> 16019387 |
M Simões1, M O Pereira, M J Vieira.
Abstract
This study shows that a short-term respirometric measurement based on the rate of oxygen uptake needed to oxidize glucose is a reliable and fast method to assess biocide efficacy against P. fluorescens cells. Respiratory activity using oxygen consumption rate, the determination of viable and nonviable cells using Live/Dead BacLight kit and colony formation units (CFU), were compared as indicators of the biocidal efficacy of ortho-phthalaldehyde (OPA). The results showed that determining the effect of OPA against P. fluorescens using the different methods leads to different conclusions. The minimum bactericidal concentration (MBC) was 80 mgl(-1), 100 mgl(-1) and 65 mgl(-1) respectively, using respiratory activity, viability using BacLight counts and culturability. The plate count method was shown to underestimate the biocidal action of OPA, whilst data from respirometry and viability using Live/Dead BacLight kit correlated strongly and were not statistically different when yellow cells were considered nonviable. Respirometry therefore represents an expeditious, non-destructive and accurate method to determine the antimicrobial action of biocides against aerobic heterotrophic bacteria.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16019387 DOI: 10.1080/08927010500066982
Source DB: PubMed Journal: Biofouling ISSN: 0892-7014 Impact factor: 3.209