Literature DB >> 16009462

Determining the performance of a commercial air purification system for reducing airborne contamination using model micro-organisms: a new test methodology.

W D Griffiths1, A Bennett, S Speight, S Parks.   

Abstract

The performance of a duct-mounted air disinfection system, designed to reduce airborne pathogens in the hospital environment, was determined using a new testing methodology. The methodology places the equipment in a test duct, a microbial aerosol is generated and then sampled simultaneously before and after the test system. This allows a percentage efficiency value to be calculated. The air disinfection system is a novel chemical-coated filter and ultraviolet (UV) radiation air purification system, operating at a flow rate of 500 m(3)/h, against aerosols of MS2 phage and Mycobacterium vaccae (surrogates of viral and mycobactericidal pathogens). A three UV lamp system was effective against airborne phages, removing an average of 97.34% of the aerosolized challenge. With the UV component switched off, the average efficiency dropped to 61.46%. This demonstrates that the chemical-coated filter component plays a more significant role than the UV radiation in destroying phages. When six UV lamps were used, the system was able to remove mycobacteria with an efficiency exceeding 99.99%. This test methodology can be used to assess manufacturers' claims of efficacy of equipment against airborne micro-organisms in the hospital environment.

Entities:  

Mesh:

Year:  2005        PMID: 16009462     DOI: 10.1016/j.jhin.2005.03.004

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  6 in total

1.  Development of a test system to apply virus-containing particles to filtering facepiece respirators for the evaluation of decontamination procedures.

Authors:  Edward Fisher; Samy Rengasamy; Dennis Viscusi; Evanly Vo; Ronald Shaffer
Journal:  Appl Environ Microbiol       Date:  2009-01-09       Impact factor: 4.792

2.  UVC LED Irradiation Effectively Inactivates Aerosolized Viruses, Bacteria, and Fungi in a Chamber-Type Air Disinfection System.

Authors:  Do-Kyun Kim; Dong-Hyun Kang
Journal:  Appl Environ Microbiol       Date:  2018-08-17       Impact factor: 4.792

Review 3.  Methods for sampling of airborne viruses.

Authors:  Daniel Verreault; Sylvain Moineau; Caroline Duchaine
Journal:  Microbiol Mol Biol Rev       Date:  2008-09       Impact factor: 11.056

4.  Comparison of five bacteriophages as models for viral aerosol studies.

Authors:  Nathalie Turgeon; Marie-Josée Toulouse; Bruno Martel; Sylvain Moineau; Caroline Duchaine
Journal:  Appl Environ Microbiol       Date:  2014-05-02       Impact factor: 4.792

5.  MS2 Coliphage as a Surrogate for 2009 Pandemic Influenza A (H1N1) Virus (pH1N1) in Surface Survival Studies on N95 Filtering Facepiece Respirators.

Authors:  A D Coulliette; K A Perry; E M Fisher; J R Edwards; R E Shaffer; J Noble-Wang
Journal:  J Int Soc Respir Prot       Date:  2014-01

6.  Methodology for modeling the microbial contamination of air filters.

Authors:  Yun Haeng Joe; Ki Young Yoon; Jungho Hwang
Journal:  PLoS One       Date:  2014-02-11       Impact factor: 3.240