Abstract
A liquid chromatography electrospray mass spectrometry (LC/ESI/MS) method has been developed to identify and quantify microcystins in fish liver and intestine. Microcystins (MCs) were extracted from 500 mg sample with methanol-water (85:25, v/v) and the extracts concentrated to 250 microl. The parameters were optimized by a full factorial 2(3) design. Neither laborious pre-treatment nor clean up were necessary. MCs were separated using conventional C18 column and an acetonitrile-acidified water (pH 3) gradient. Negative samples (without MCs) were discriminated by liquid chromatography diode array detection (LC/DAD). The limits of detection (LOD) and the limits of quantification (LOQ) resulted equal for MC-RR, MC-YR, and MC-LR and were 0.1 and 0.5 microg g(-1), respectively. MCs recoveries at three levels in spiked samples (0.5-3.0 microg g(-1)) were > 92%, with relative standards deviations (RSDs) < 16% for liver samples and > 68% with RSDs < 18% for intestine samples. The proposed method was applied to determine MC-LR in exposed fish to evaluate the bioaccumulation risk. The results showed the transference of MC-LR from cyanobacterial cells to fish tissues.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16008059 DOI: 10.1016/j.chroma.2005.05.029
Source DB: PubMed Journal: J Chromatogr A ISSN: 0021-9673 Impact factor: 4.759