Literature DB >> 1600763

Exposure of health care workers to aerosolized pentamidine.

T G O'Riordan1, G C Smaldone.   

Abstract

In patients, urinary levels of pentamidine have been shown to reflect pulmonary deposition of aerosolized drug. Using urinary levels and air filter samples, we assessed factors responsible for health care worker (HCW) exposure. We measured serial urine samples in HCWs who administered aerosol pentamidine over an 11-month period and compared them with serial urine levels measured over 30 days in a normal volunteer in whose lungs a known amount of pentamidine (3.39 mg) had been deposited. Ambient exposure to pentamidine was determined by continuous high volume air sampling in the treatment room during routine therapy. In addition, the amount of pentamidine released by six HIV-positive subjects, performing tidal breathing with a Respirgard II nebulizer in an airtight booth, was measured by extracting air from the booth through a filter. The effect of adding noseclips, of coughing (with nebulizer shut down), and of removing the nebulizer from the patient's mouth without turning it off, were determined. Pentamidine in the urine of the normal volunteer reached a peak concentration of 9.5 ng/mg creatinine/ml and was detectable for 30 days following the exposure. In HCWs, pentamidine was detected intermittently in four of five individuals with levels as high as 18.2 ng/mg creatinine/ml. Samples of ambient treatment room air indicated small daily releases of pentamidine (0.013 +/- 0.02 mg per patient treated), but simultaneous urine levels in HCWs were negative. The data from the airtight booth revealed that removing the nebulizer from a patient's mouth without turning it off caused a 360-fold increased in pentamidine release compared to tidal breathing. Coughing resulted in a 6.9 (range 0.9-14.2)-fold increase in release, while the addition of noseclips had no significant effect. The pattern of intermittently positive urine tests and the low levels of ambient pentamidine detected in the air of the treatment room suggest that HCWs are being exposed to episodic but high concentrations of pentamidine. High level exposure is most likely to occur during treatment interruptions which are usually precipitated by coughing episodes. Because of the intermittent pattern of exposure and slow clearance of pentamidine, urine assay is useful for detecting high intermittent exposure. Random air sampling is a sensitive indicator of low level exposures but may not detect episodic high level releases.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1600763     DOI: 10.1378/chest.101.6.1494

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  5 in total

1.  Precautionary Practices of Respiratory Therapists and Other Health-Care Practitioners Who Administer Aerosolized Medications.

Authors:  Rebecca J Tsai; James M Boiano; Andrea L Steege; Marie H Sweeney
Journal:  Respir Care       Date:  2015-07-07       Impact factor: 2.258

2.  Pentamidine aerosols and environmental contamination: health-care workers at risk.

Authors:  J J Ros; M C Langen; P C Stallen; A W Lenderink
Journal:  Pharm World Sci       Date:  1996-08

3.  Containment of procedure-associated aerosols by an extractor tent: effect on nebulized drug particle dispersal.

Authors:  M Fennelly; J Keane; L Dolan; B J Plant; D J O'Connor; J R Sodeau; M B Prentice
Journal:  J Hosp Infect       Date:  2021-01-20       Impact factor: 3.926

4.  Primary prophylaxis of bacterial infections and Pneumocystis jirovecii pneumonia in patients with hematologic malignancies and solid tumors: 2020 updated guidelines of the Infectious Diseases Working Party of the German Society of Hematology and Medical Oncology (AGIHO/DGHO).

Authors:  Annika Y Classen; Larissa Henze; Marie von Lilienfeld-Toal; Georg Maschmeyer; Michael Sandherr; Luisa Durán Graeff; Nael Alakel; Maximilian Christopeit; Stefan W Krause; Karin Mayer; Silke Neumann; Oliver A Cornely; Olaf Penack; Florian Weißinger; Hans-Heinrich Wolf; Jörg Janne Vehreschild
Journal:  Ann Hematol       Date:  2021-04-13       Impact factor: 3.673

5.  Nebulization: A potential source of SARS-CoV-2 transmission.

Authors:  G Reychler; L Vecellio; J C Dubus
Journal:  Respir Med Res       Date:  2020-08-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.