Literature DB >> 16001628

Sealing the thoracic duct with ultrasonic coagulating shears.

Yoshiaki Kajiyama1, Yoshimi Iwanuma, Natsumi Tomita, Takayuki Amano, Kimiaki Hattori, Masahiko Tsurumaru.   

Abstract

BACKGROUND/AIMS: Ultrasonic coagulating shears were developed as an endosurgical device that allows cutting of vessels without ligation. In this study, we obtained basic data on the feasibility of dividing and sealing the thoracic duct by using ultrasonic coagulating shears.
METHODOLOGY: We obtained the thoracic duct and the left gastric artery from surgical specimens of 27 patients. After one end of each vessel was sealed using ultrasonic coagulating shears, we recorded the bursting pressure. The sealed ends of the vessels were also examined histopathologically.
RESULTS: The mean bursting pressure of the thoracic duct was high enough to support the clinical use of this device, and was significantly higher than that of the left gastric artery (p<0.001). Microscopic examination of the sealed vessels showed that degenerated collagen fibers were more homogeneous and covered a significantly larger area in the thoracic duct than in the left gastric artery (p<0.001).
CONCLUSIONS: The present study provides a basis for using ultrasonic coagulating shears to seal the thoracic duct and possibly lymph node dissection.

Entities:  

Mesh:

Year:  2005        PMID: 16001628

Source DB:  PubMed          Journal:  Hepatogastroenterology        ISSN: 0172-6390


  4 in total

1.  BiClamp forceps significantly shorten the operation time for breast surgery.

Authors:  Hideki Takeuchi; Toshiaki Saeki; Takashi Shigekawa; Hiroshi Sano; Noriko Nakamiya; Kazuo Matsuura; Misono Misumi; Takao Takahashi; Nobuko Fujiuchi; Katsuhiko Okubo; Akihiko Osaki; Takaki Sakurai; Isamu Koyama
Journal:  Surg Today       Date:  2010-07-30       Impact factor: 2.549

Review 2.  Endoscopic inguinal lymph node dissection for penile carcinoma: the developing of a novel technique.

Authors:  René Sotelo; Rafael Sanchez-Salas; Rafael Clavijo
Journal:  World J Urol       Date:  2009-02-17       Impact factor: 4.226

3.  Evaluation of the Learning Curve of Hand-Assisted Laparoscopic Donor Nephrectomy.

Authors:  Bum Sik Tae; Ulanbek Balpukov; Hyeon Hoe Kim; Chang Wook Jeong
Journal:  Ann Transplant       Date:  2018-08-07       Impact factor: 1.530

Review 4.  Advances and safe use of energy devices in lung cancer surgery.

Authors:  Takahiro Homma
Journal:  Gen Thorac Cardiovasc Surg       Date:  2022-02-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.