Literature DB >> 16000995

A general equation for estimating glomerular filtration rate from a single plasma sample.

John S Fleming1, Linda Persaud, Maureen A Zivanovic.   

Abstract

OBJECTIVES: Glomerular filtration rate (GFR) may be estimated from a single plasma sample measurement using empirical equations. This method forms the basis of international guidelines on GFR measurement. New guidelines have recently been recommended by the British Nuclear Medicine Society (BNMS). These use the slope-intercept technique in which several samples are obtained. Quality control of measurement may be achieved by comparison with the individual single-sample values. This paper compares international guideline single-sample estimates of GFR with the new BNMS method and derives an improved general single-sample equation.
METHODS: GFR measurements using Tc-DTPA were performed on 180 adults and 100 children using samples at approximately 2 h and 3 h and a further 45 adults with samples at 2, 3 and 4 h. The two-sample values obtained using the BNMS guideline method were compared to one-sample estimates obtained using (1) international guidelines and (2) a new equation derived from the data. The new equation was evaluated in a further 145 subjects.
RESULTS: The international guidelines technique had systematic differences between the one-sample and two-sample estimates of GFR. The new equation had minimal systematic error and reduced random error (standard error of the estimate 4.5 ml . min per 1.73 m).
CONCLUSIONS: There were significant differences between GFR values obtained using the international guidelines single-sample method and the slope-intercept method described in the BNMS guidelines. The new equation described in this paper gave considerably improved agreement and is recommended if single-sample estimates are to be used as quality control for BNMS guideline measurements.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16000995     DOI: 10.1097/01.mnm.0000171783.18650.80

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  8 in total

1.  Estimating glomerular filtration rate in children: evaluation of creatinine- and cystatin C-based equations.

Authors:  Cathrin L Salvador; Camilla Tøndel; Alexander D Rowe; Anna Bjerre; Atle Brun; Damien Brackman; Lars Mørkrid
Journal:  Pediatr Nephrol       Date:  2018-08-31       Impact factor: 3.714

Review 2.  Ontogeny of drug elimination by the human kidney.

Authors:  Nancy Chen; Katarina Aleksa; Cindy Woodland; Michael Rieder; Gideon Koren
Journal:  Pediatr Nephrol       Date:  2005-12-06       Impact factor: 3.714

3.  Iohexol plasma clearance for measuring glomerular filtration rate: effect of different ways to calculate the area under the curve.

Authors:  Hans Pottel; Elke Schaeffner; Natalie Ebert; Markus van der Giet; Pierre Delanaye
Journal:  BMC Nephrol       Date:  2021-05-05       Impact factor: 2.388

4.  Iohexol plasma clearance in children: validation of multiple formulas and single-point sampling times.

Authors:  Camilla Tøndel; Cathrin Lytomt Salvador; Karl Ove Hufthammer; Bjørn Bolann; Damien Brackman; Anna Bjerre; Einar Svarstad; Atle Brun
Journal:  Pediatr Nephrol       Date:  2017-11-13       Impact factor: 3.714

5.  Kidney Perfusion in Contrast-Enhanced Ultrasound (CEUS) Correlates with Renal Function in Living Kidney Donors.

Authors:  Nasrin El-Bandar; Markus H Lerchbaumer; Robert Peters; Andreas Maxeiner; Katja Kotsch; Arne Sattler; Kurt Miller; Thorsten Schlomm; Bernd Hamm; Klemens Budde; Lutz Liefeldt; Thomas Fischer; Frank Friedersdorff
Journal:  J Clin Med       Date:  2022-02-01       Impact factor: 4.241

6.  Accuracy of single intravenous access iohexol GFR in children is hampered by marker contamination.

Authors:  Thea Tislevoll Eide; Karl Ove Hufthammer; Atle Brun; Damien Brackman; Einar Svarstad; Camilla Tøndel
Journal:  Sci Rep       Date:  2021-12-01       Impact factor: 4.379

7.  Accuracy of iohexol plasma clearance for GFR-determination: a comparison between single and dual sampling.

Authors:  Yong Zhang; Zhun Sui; Ze Yu; Tai Feng Li; Wan Yu Feng; Li Zuo
Journal:  BMC Nephrol       Date:  2018-07-11       Impact factor: 2.388

8.  An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel embedded quality assurance features.

Authors:  Ran Klein; Simin Razavi; Rayhan Memon; Lionel S Zuckier
Journal:  Nucl Med Commun       Date:  2019-01       Impact factor: 1.690

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.