Literature DB >> 16000218

Factorial analysis of variables influencing stress in all-ceramic crowns.

E Dianne Rekow1, Masly Harsono, Mal Janal, Van P Thompson, Guangming Zhang.   

Abstract

OBJECTIVE: The objective of this investigation was to evaluate the relative contribution of variables in the crown-cement-tooth system that can influence magnitude of maximum principal stress in all-ceramic crowns. METHODS.: Factorial analysis was performed to calculate the coefficients of main and interactive effects of seven variables on maximum stress distribution in a series of finite element models of an axisymmetric stylized ceramic crown-cement-tooth system. Variables investigated at two levels were selected for their clinical relevance and included those relating to crown material and geometry (thickness and cuspal incline), cement modulus and thickness, supporting tooth core, and position at which the occlusal load was applied.
RESULTS: The average principal stress for all combinations of all variables was 135.1 MPa but stress magnitude ranged from 73.7 to 214.0 MPa. Crown material and thickness are of primary importance in stress magnitude but other variables (cement modulus, load position, and supporting tooth core) also contribute to the stress magnitude. Interactions between these variables can have an important influence, particularly since the stress in the crown is not necessarily sensitive to the same factors for all crown material systems. SIGNIFICANCE: Comprehensive evaluation of stress in a crown of a crown-cement-tooth system must integrate the influence of single variables and their interactions.

Mesh:

Substances:

Year:  2005        PMID: 16000218     DOI: 10.1016/j.dental.2005.04.010

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  28 in total

1.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

2.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

3.  Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials.

Authors:  Joana Schönberger; Kurt-Jürgen Erdelt; Daniel Bäumer; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-02-04       Impact factor: 3.573

4.  3D finite element non linear analysis on the stress state at bone-implant interface in dental osteointegrated implants.

Authors:  G Sannino; G Marra; L Feo; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2011-01-13

5.  Reliability estimation for single-unit ceramic crown restorations.

Authors:  H Lekesiz
Journal:  J Dent Res       Date:  2014-07-21       Impact factor: 6.116

Review 6.  Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses.

Authors:  Kenneth J Anusavice
Journal:  Dent Mater       Date:  2012-01       Impact factor: 5.304

7.  Effect of seating forces on cement-ceramic adhesion in microtensile bond tests.

Authors:  Susana María Salazar Marocho; Mutlu Ozcan; Regina Amaral; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  Clin Oral Investig       Date:  2012-01-13       Impact factor: 3.573

8.  Influence of finish line in the distribution of stress trough an all ceramic implant-supported crown.: A 3D Finite Element Analysis.

Authors:  G Sannino; F Gloria; L Ottria; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2010-03-04

9.  Morphing methods to parameterize specimen-specific finite element model geometries.

Authors:  Ian A Sigal; Hongli Yang; Michael D Roberts; J Crawford Downs
Journal:  J Biomech       Date:  2009-10-29       Impact factor: 2.712

10.  Design features of a three-dimensional molar crown and related maximum principal stress. A finite element model study.

Authors:  Brian T Rafferty; Malvin N Janal; Ricardo A Zavanelli; Nelson R F A Silva; E Dianne Rekow; Van P Thompson; Paulo G Coelho
Journal:  Dent Mater       Date:  2009-10-25       Impact factor: 5.304

View more