Reconstruction with distraction osteogenesis for juxta-articular nonunions with bone loss.

Tamon Kabata1, Hiroyuki Tsuchiya, Keisuke Sakurakichi, Teruhisa Yamashiro, Koji Watanabe, Kasuro Tomita.   

Abstract

BACKGROUND: Nonunions of a juxta-articular lesion with bone loss, which represent a challenging therapeutic problem, were treated using external fixation and distraction osteogenesis.
METHODS: Seven juxta-articular nonunions (five septic and two aseptic) were treated. The location of the nonunion was the distal femur in four patients, the proximal tibia in one patient, and the distal tibia in two patients. All of them were located within 5 cm from the affected joints. Preoperative limb shortening was present in six cases, averaging 2.9 cm (range, 1-7 cm). The reconstructive procedure consisted of refreshment of the nonunion site, deformity correction, stabilization by external fixation, and lengthening to eliminate leg length discrepancy or to fill the defect. Shortening-distraction was applied to six patients and bone transport to one patient for reconstruction. Intramedullary nailing to reduce the duration of external fixation was simultaneously performed in two cases. All the patients had at least 1 year of follow-up evaluation.
RESULTS: Osseous union without angular deformity or leg length discrepancy greater than 1 cm was achieved in all patients. The mean amount of lengthening was 5.8 cm (range, 2.2-10.0 cm). The mean external fixation period was 219 days (range, 98-317 days), and the mean external fixation index was 34.4 days/cm (range, 24.5-47.6 days/cm). All patients reported excellent pain reduction. There were no recurrences of infection in five patients with prior history of osteomyelitis. The functional results were categorized as excellent in two, good in three, and fair in two.
CONCLUSION: Despite the length of postoperative external fixation, distraction osteogenesis can be a valuable alternative for the treatment of juxta-articular nonunions.

Entities:  

Mesh:

Year:  2005        PMID: 15995473     DOI: 10.1097/01.ta.0000169806.08994.e2

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  5 in total

1.  Circular external fixation frames with divergent half pins: a pilot biomechanical study.

Authors:  Christopher Lenarz; Gary Bledsoe; J Tracy Watson
Journal:  Clin Orthop Relat Res       Date:  2008-09-18       Impact factor: 4.176

2.  Treatment outcomes for infected juxta-articular knee nonunions.

Authors:  A Lagaras; V Kontogeorgakos; S Varitimidis; K N Malizos
Journal:  Hippokratia       Date:  2018 Oct-Dec       Impact factor: 0.471

Review 3.  External fixators: looking beyond the hardware maze.

Authors:  Kimia Khalatbari Kani; Jack A Porrino; Felix S Chew
Journal:  Skeletal Radiol       Date:  2019-09-12       Impact factor: 2.199

4.  Treatment of atrophic femoral non-unions according to the diamond concept: Results of one- and two-step surgical procedure.

Authors:  Arash Moghaddam; Benjamin Thaler; Thomas Bruckner; Michael Tanner; Gerhard Schmidmaier
Journal:  J Orthop       Date:  2016-11-02

5.  Femoral reconstruction using external fixation.

Authors:  Yevgeniy Palatnik; S Robert Rozbruch
Journal:  Adv Orthop       Date:  2011-03-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.