Literature DB >> 15994999

Outcome of first-trimester pregnancies with slow embryonic heart rate at 6-7 weeks gestation and normal heart rate by 8 weeks at US.

Peter M Doubilet1, Carol B Benson.   

Abstract

PURPOSE: To determine retrospectively the outcome of pregnancies in which the embryo has a slow heart rate at 6.0-7.0 weeks gestation and a normal heart rate at follow-up ultrasonography (US) by 8.0 weeks gestation.
MATERIALS AND METHODS: Institutional review board approval was granted; informed consent was not required. The study was Health Insurance Portability and Accountability Act compliant. Singleton pregnancies with an embryonic heart rate measured on a 6.0-7.0-week US scan were identified. The heart rate was classified as slow if it was fewer than 90 beats per minute prior to 6.3 weeks or fewer than 110 beats/min at 6.3-7.0 weeks, normal if it was 100 or more beats/min at less than 6.3 weeks or 120 or more beats/min at 6.3-7.0 weeks, or borderline if it was 90-99 beats/min prior to 6.3 weeks or 110-119 beats/min at 6.3-7.0 weeks. Pregnancies were excluded from the analysis if they were lost to follow-up before the end of first trimester. The Fisher exact test was used for all statistical comparisons.
RESULTS: The rates of first-trimester demise were 60.6% for pregnancies with slow heart rates at 6.0-7.0 weeks (188 of 310), 17.4% for those with borderline heart rates (103 of 593), and 9.1% for those with normal heart rates (186 of 2034). There were 59 pregnancies with a slow heart rate at 6.0-7.0 weeks and a normal heart rate at follow-up US by 8.0 weeks; 15 (25.4%) resulted in first-trimester demise. This rate of demise was significantly higher than that of 7.2% (28 of 390) in pregnancies with a normal heart rate at 6.0-7.0 weeks and a normal heart rate by 8.0 weeks (P <.001, Fisher exact test). Pregnancies with a borderline heart rate early in pregnancy followed by a normal heart rate had a demise rate of 7.6% (nine of 118), which is similar to those with normal heart rates early in pregnancy followed by normal heart rates at follow-up (P = .84).
CONCLUSION: When a slow embryonic heart rate is detected at 6.0-7.0 weeks, the likelihood of subsequent first-trimester demise remains elevated (approximately 25%) even if the heart rate is normal at follow-up. In such pregnancies, at least one follow-up scan in late first trimester is warranted.

Mesh:

Year:  2005        PMID: 15994999     DOI: 10.1148/radiol.2362040880

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  Correlation of Serum CA-125 and Progesterone Levels with Ultrasound Markers in The Prediction of Pregnancy Outcome in Threatened Miscarriage.

Authors:  Maged Al Mohamady; Ghada Abdel Fattah; Eman Elkattan; Rasha Bayoumy; Dalia Ahmed Hamed
Journal:  Int J Fertil Steril       Date:  2015-12-23

2.  Control of the heart rate of rat embryos during the organogenic period.

Authors:  Helen E Ritchie; Carolina Ragnerstam; Elin Gustafsson; Johanna M Jonsson; William S Webster
Journal:  Hypoxia (Auckl)       Date:  2016-11-08

3.  Long-term programming effects on blood pressure following gestational exposure to the IKr blocker Dofetilide.

Authors:  Louise Prestipino; Jaimie W Polson; Elisabeth Brolin; Helen E Ritchie
Journal:  Physiol Rep       Date:  2018-03

Review 4.  Development of the Human Placenta and Fetal Heart: Synergic or Independent?

Authors:  Graham J Burton; Eric Jauniaux
Journal:  Front Physiol       Date:  2018-04-12       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.