Literature DB >> 15993890

A comparability study of the emerging protein array platforms with established ELISA procedures.

Susan Pang1, Jodie Smith, David Onley, Julie Reeve, Michael Walker, Carole Foy.   

Abstract

Recent developments in microarray technology have made it possible to perform immunoassays in a multiplexed format. This ability is highly desirable given the potential for greater throughput analysis. In spite of the obvious advantages, a number of issues arise as a result of multiplexing the reactions. In this study, we have assessed the performance characteristics that are associated with the transfer of technology from a uniplexed to a multiplexed format. Two solution phase array platforms were chosen for this study: the commercially available Luminex(100) xMap system (Austin, Texas, USA) and the UltraPlex technology devised by SmartBead Technologies Ltd. (Cambridge, UK). For this comparative study, a test for the presence of six autoantibodies in a selection of human patient serum samples was chosen as a model system. The multiplexed Luminex xMap and SmartBead UltraPlex assays were generally comparable. However, both systems generated some results that were at variance with those obtained by ELISA. The different methods used for the assignment of the cut-off levels for each of the assays within any given platform was identified as the major source of these non-concordant results. The present study demonstrates that array platforms have the potential to be used in immunodiagnostics providing that suitable cut-off levels are established.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15993890     DOI: 10.1016/j.jim.2005.04.007

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  16 in total

Review 1.  Multiplexed protein measurement: technologies and applications of protein and antibody arrays.

Authors:  Stephen F Kingsmore
Journal:  Nat Rev Drug Discov       Date:  2006-04       Impact factor: 84.694

2.  Multiplex bead array assays: performance evaluation and comparison of sensitivity to ELISA.

Authors:  Mohamed F Elshal; J Philip McCoy
Journal:  Methods       Date:  2006-04       Impact factor: 3.608

3.  Sensitive single-molecule protein quantification and protein complex detection in a microarray format.

Authors:  Lee A Tessler; Robi D Mitra
Journal:  Proteomics       Date:  2011-11-23       Impact factor: 3.984

4.  Biochips that sequentially capture and focus antigens for immunoaffinity MALDI-TOF MS: a new tool for biomarker verification.

Authors:  Heather Ann Brauer; Paul D Lampe; Yutaka Y Yasui; Nobuyuki Hamajima; Mark L Stolowitz
Journal:  Proteomics       Date:  2010-11       Impact factor: 3.984

5.  Multiplex analysis of cytokines as biomarkers that differentiate benign and malignant thyroid diseases.

Authors:  Faina Linkov; Robert L Ferris; Zoya Yurkovetsky; Adele Marrangoni; Lyudmila Velikokhatnaya; William Gooding; Brian Nolan; Matthew Winans; Eric R Siegel; Anna Lokshin; Brendan C Stack
Journal:  Proteomics Clin Appl       Date:  2008-10-10       Impact factor: 3.494

6.  Effects of serum and plasma matrices on multiplex immunoassays.

Authors:  Yael Rosenberg-Hasson; Leo Hansmann; Michaela Liedtke; Iris Herschmann; Holden T Maecker
Journal:  Immunol Res       Date:  2014-05       Impact factor: 2.829

Review 7.  Perspective on optical biosensors and integrated sensor systems.

Authors:  Frances S Ligler
Journal:  Anal Chem       Date:  2009-01-15       Impact factor: 6.986

Review 8.  Mass spectrometry based targeted protein quantification: methods and applications.

Authors:  Sheng Pan; Ruedi Aebersold; Ru Chen; John Rush; David R Goodlett; Martin W McIntosh; Jing Zhang; Teresa A Brentnall
Journal:  J Proteome Res       Date:  2009-02       Impact factor: 4.466

9.  Simultaneous detection of antibodies against Apx toxins ApxI, ApxII, ApxIII, and ApxIV in pigs with known and unknown Actinobacillus pleuropneumoniae exposure using a multiplexing liquid array platform.

Authors:  Luis G Giménez-Lirola; Yong-Hou Jiang; Dong Sun; Hai Hoang; Kyoung-Jin Yoon; Patrick G Halbur; Tanja Opriessnig
Journal:  Clin Vaccine Immunol       Date:  2013-11-13

10.  Clinical associations of anti-CENP-B and anti-Scl70 antibody levels measured by multiplexed fluorescent microsphere immunoassay in systemic sclerosis.

Authors:  Alessandro Volpe; Orazio Ruzzenente; Paola Caramaschi; Sara Pieropan; Ilaria Tinazzi; Antonio Carletto; Lisa Maria Bambara; Domenico Biasi
Journal:  Rheumatol Int       Date:  2009-02-05       Impact factor: 2.631

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.