Literature DB >> 15993298

Application of the central composite design and response surface methodology to the advanced treatment of olive oil processing wastewater using Fenton's peroxidation.

M Ahmadi1, F Vahabzadeh, B Bonakdarpour, E Mofarrah, M Mehranian.   

Abstract

The central composite design (CCD) technique was used to study the effect of the Fenton's peroxidation on the removal of organic pollutants from olive oil mill wastewater (OMW). The ratio of hydrogen peroxide-to-Fe(II) (x1) was between 1.67 and 8.33. Fe(II) concentration was constant at 0.03 M while the H2O2 concentration was set at three levels: 0.05, 0.15 and 0.25 M. Based on the molarity ratio, the selected ratio were in the low range of Fe(II)-to-H2O2 ratio (<<1). While based on the wt/wt ratio, the tested Fe(II)-to-H2O2 ratios were in the range of < or =1:5. pH (x2) was between 3 and 5. The concentration of OMW (x3) was varied between 40 and 100%. The influence of these three independent variables on the four dependent variables, i.e. COD, total phenolics (TP), color and aromaticity removal was evaluated using a second-order polynomial multiple regression model. Analysis of variance (ANOVA) showed a high coefficient of determination (R2) value of 0.902-0.998, thus ensuring a satisfactory adjustment of the second-order regression model with the experimental data. H2O2-to-Fe(II) ratio had significant effect on all the four dependent variables. The positive sign for the regression coefficient of this regressor variable indicated that the level of the pollutant removal increased with the increased levels of factor x1 from 1.67 to 8.33 and this effect was the most pronounced for TP removal. pH had also significant effect on the pollutant removal and the effect was the most noticeable for TP reduction. The negative coefficient of this variable (pH) indicated that level of the pollutant removal decreased as the pH increased from 3 to 5. The negative coefficient of the interaction between variable x1 and x2 indicated that a simultaneous increase in H2O2-to-Fe(II) ratio with decrease in the pH of the reaction led to an increase in the COD, TP and color removal. Quadratic models were predicted for the response variable, i.e. pollutant removal, and the maximum model-predicted removals were 56, 100, 33 and 32% for COD, TP, color and aromaticity, respectively. Optimum conditions for this wastewater treatment was obtained based on the performance of the Fenton's peroxidation in the experiment where the H2O2-to-Fe(II) ratio was at its high level (8.33) and the pH and OMW concentration were 4 and 70%, respectively.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15993298     DOI: 10.1016/j.jhazmat.2005.03.042

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  18 in total

1.  Degradation and biodegradability improvement of the olive mill wastewater by peroxi-electrocoagulation/electrooxidation-electroflotation process with bipolar aluminum electrodes.

Authors:  Yahya Esfandyari; Yousef Mahdavi; Mahdi Seyedsalehi; Mohammad Hoseini; Gholam Hossein Safari; Mohammad Ghanbari Ghozikali; Hossein Kamani; Jalil Jaafari
Journal:  Environ Sci Pollut Res Int       Date:  2014-11-20       Impact factor: 4.223

2.  Modeling and optimization of the flocculation processes for removal of cationic and anionic dyes from water by an amphoteric grafting chitosan-based flocculant using response surface methodology.

Authors:  Hu Wu; Ran Yang; Ruihua Li; Chao Long; Hu Yang; Aimin Li
Journal:  Environ Sci Pollut Res Int       Date:  2015-04-30       Impact factor: 4.223

3.  The use of a natural coagulant (Opuntia ficus-indica) in the removal for organic materials of textile effluents.

Authors:  Maísa Tatiane Ferreira de Souza; Elizangela Ambrosio; Cibele Andrade de Almeida; Thábata Karoliny Formicoli de Souza Freitas; Lídia Brizola Santos; Vitor de Cinque Almeida; Juliana Carla Garcia
Journal:  Environ Monit Assess       Date:  2014-05-02       Impact factor: 2.513

4.  Operational parameters optimization for remediation of crude oil-polluted water in floating treatment wetlands using response surface methodology.

Authors:  Khadeeja Rehman; Muhammad Arslan; Jochen A Müller; Muhammad Saeed; Samina Anwar; Ejazul Islam; Asma Imran; Imran Amin; Tanveer Mustafa; Samina Iqbal; Muhammad Afzal
Journal:  Sci Rep       Date:  2022-03-16       Impact factor: 4.379

5.  Dynamic modelling for cork boiling wastewater treatment at pilot plant scale.

Authors:  E De Torres-Socías; A Cabrera-Reina; M J Trinidad; F J Yuste; I Oller; S Malato
Journal:  Environ Sci Pollut Res Int       Date:  2014-05-09       Impact factor: 4.223

6.  A new approach to evaluate toxic metal transport in a catchment.

Authors:  Emilli Frachini; Leonel Vinicius Constantino; Taufik Abrao; Maria Josefa Santos
Journal:  Environ Monit Assess       Date:  2020-03-13       Impact factor: 2.513

7.  Phenol degradation by Fenton-like process.

Authors:  Antover Panazzolo Sarmento; Alisson Carraro Borges; Antonio Teixeira de Matos; Lincoln Lucílio Romualdo
Journal:  Environ Sci Pollut Res Int       Date:  2016-06-10       Impact factor: 4.223

8.  Synthetic olive mill wastewater treatment by Fenton's process in batch and continuous reactors operation.

Authors:  Bruno M Esteves; Carmen S D Rodrigues; Luís M Madeira
Journal:  Environ Sci Pollut Res Int       Date:  2017-11-04       Impact factor: 4.223

9.  Degradation of 4-Chloro-3,5-Dimethylphenol by a Heterogeneous Fenton-Like Reaction Using Nanoscale Zero-Valent Iron Catalysts.

Authors:  Lejin Xu; Jianlong Wang
Journal:  Environ Eng Sci       Date:  2013-06       Impact factor: 1.907

10.  Reducing the pollutant load of olive mill wastewater by photocatalytic membranes and monitoring the process using both tyrosinase biosensor and COD test.

Authors:  Elisabetta Martini; Mauro Tomassetti; Luigi Campanella; Antonio Fortuna
Journal:  Front Chem       Date:  2013-12-16       Impact factor: 5.221

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.