Literature DB >> 15992604

Statistical investigation of polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of Houston, Texas.

Loren H Raun1, Oscar Correa, Hanadi Rifai, Monica Suarez, Larry Koenig.   

Abstract

Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (dioxins and furans) are persistent, bioaccumulative and highly toxic chemical constituents that appear in the environment at very low and difficult to measure levels. Although dioxins and furans are widely recognized as toxic contaminants needing regulation, their temporal and spatial concentration profiles and the factors impacting their partitioning and congener distribution are only moderately understood. This paper presents the results from one of the most extensive ambient air dioxin and furan sampling efforts conducted in a geographic area to date. The data consist of monthly ambient concentrations of 17 of the most toxic congeners of dioxins and furans collected at five locations in Houston, Texas over a calendar year. The results showed a total annual mean dioxin and furan congener concentration of 1047 fg/m3 and an annual mean summation operatorI-TEQ concentration of 15 fg I-TEQ/m3 (16 fg WHO-TEQ/m3). These results, when compared with proximate data from the USEPA National Dioxin Ambient Monitoring Network (NDAMN), revealed significant (at the P0.05 level) differences between Houston and the NDAMN sites, suggesting the existence of local dioxin sources. A temporal analysis of the data showed that the congener concentration distribution varies over time, depending on the level of chlorination, type of congener, and temperature. The results also suggested that the fluctuations of congener concentrations and I-TEQ concentrations are closely correlated with minimum relative humidity, mean temperature, and mean NOx concentration.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15992604     DOI: 10.1016/j.chemosphere.2004.12.057

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  5 in total

1.  Effects of basin topography and monsoon conditions on transport and occurrence of atmospheric PCDD/Fs in the Taichung Basin.

Authors:  Chao-Kai Huang; Jeng-Jong Liang
Journal:  Environ Sci Pollut Res Int       Date:  2011-03-23       Impact factor: 4.223

2.  Passive air sampling for determining the levels of ambient PCDD/Fs and their seasonal and spatial variations and inhalation risk in Shanghai, China.

Authors:  Yajun Tian; Zhiqiang Nie; Shulei Tian; Feng Liu; Jie He; Yufei Yang; Xingrun Wang; Qingqi Die; Yanyan Fang; Qifei Huang
Journal:  Environ Sci Pollut Res Int       Date:  2015-05-05       Impact factor: 4.223

3.  Occurrence and distribution of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in industrial and domestic sewage sludge.

Authors:  Aparna Balasubramani; Hanadi S Rifai
Journal:  Environ Sci Pollut Res Int       Date:  2015-05-21       Impact factor: 4.223

4.  Seasonal variation of PCDD/Fs in the metropolis of Istanbul, Turkey.

Authors:  Gulten Gunes; Arslan Saral
Journal:  Environ Sci Pollut Res Int       Date:  2014-04-11       Impact factor: 4.223

5.  Congener profiles and source-wise phase partitioning analysis of PCDDs/Fs and PCBs in Gyeonggi-do ambient air, South Korea.

Authors:  Jongwon Heo; Donggi Kim; Gangwoong Lee
Journal:  Int J Environ Res Public Health       Date:  2014-10-24       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.