Literature DB >> 15984691

Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors.

S Richard1, J H Siewerdsen, D A Jaffray, D J Moseley, B Bakhtiar.   

Abstract

Analysis of detective quantum efficiency (DQE) is an important component of the investigation of imaging performance for flat-panel detectors (FPDs). Conventional descriptions of DQE are limited, however, in that they take no account of anatomical noise (i.e., image fluctuations caused by overlying anatomy), even though such noise can be the most significant limitation to detectability, often outweighing quantum or electronic noise. We incorporate anatomical noise in experimental and theoretical descriptions of the "generalized DQE" by including a spatial-frequency-dependent noise-power term, S(B), corresponding to background anatomical fluctuations. Cascaded systems analysis (CSA) of the generalized DQE reveals tradeoffs between anatomical noise and the factors that govern quantum noise. We extend such analysis to dual-energy (DE) imaging, in which the overlying anatomical structure is selectively removed in image reconstructions by combining projections acquired at low and high kVp. The effectiveness of DE imaging in removing anatomical noise is quantified by measurement of S(B) in an anthropomorphic phantom. Combining the generalized DQE with an idealized task function to yield the detectability index, we show that anatomical noise dramatically influences task-based performance, system design, and optimization. For the case of radiography, the analysis resolves a fundamental and illustrative quandary: The effect of kVp on imaging performance, which is poorly described by conventional DQE analysis but is clarified by consideration of the generalized DQE. For the case of DE imaging, extension of a generalized CSA methodology reveals a potentially powerful guide to system optimization through the optimal selection of the tissue cancellation parameter. Generalized task-based analysis for DE imaging shows an improvement in the detectability index by more than a factor of 2 compared to conventional radiography for idealized detection tasks.

Mesh:

Year:  2005        PMID: 15984691     DOI: 10.1118/1.1901203

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: a phantom study.

Authors:  T Gomi; M Nakajima; H Fujiwara; T Takeda; K Saito; T Umeda; K Sakaguchi
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

2.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

4.  A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2019-03-27       Impact factor: 10.048

Review 5.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

6.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

7.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

Authors:  Grace J Gang; Wojciech Zbijewski; J Webster Stayman; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

9.  Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: effect of 2D/3D apertures and sampling.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

10.  The effect of angular dose distribution on the detection of microcalcifications in digital breast tomosynthesis.

Authors:  Yue-Houng Hu; Wei Zhao
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.