Literature DB >> 15983190

Assessing the predictive accuracy of QUICKI as a surrogate index for insulin sensitivity using a calibration model.

Hui Chen1, Gail Sullivan, Michael J Quon.   

Abstract

The quantitative insulin-sensitivity check index (QUICKI) has an excellent linear correlation with the glucose clamp index of insulin sensitivity (SI(Clamp)) that is better than that of many other surrogate indexes. However, correlation between a surrogate and reference standard may improve as variability between subjects in a cohort increases (i.e., with an increased range of values). Correlation may be excellent even when prediction of reference values by the surrogate is poor. Thus, it is important to evaluate the ability of QUICKI to accurately predict insulin sensitivity as determined by the reference glucose clamp method. In the present study, we used a calibration model to compare the ability of QUICKI and other simple surrogates to predict SI(Clamp). Predictive accuracy was evaluated by both root mean squared error of prediction as well as a more robust leave-one-out cross-validation-type root mean squared error of prediction (CVPE). Based on data from 116 glucose clamps obtained from nonobese, obese, type 2 diabetic, and hypertensive subjects, we found that QUICKI and log (homeostasis model assessment [HOMA]) were both excellent at predicting SI(Clamp) (CVPE = 1.45 and 1.51, respectively) and significantly better than HOMA, 1/HOMA, and fasting insulin (CVPE = 3.17, P < 0.001; 1.67, P < 0.02; and 2.85, P < 0.001, respectively). QUICKI and log(HOMA) also had the narrowest distribution of residuals (measured SI(Clamp) - predicted SI(Clamp)). In a subset of subjects (n = 78) who also underwent a frequently sampled intravenous glucose tolerance test with minimal model analysis, QUICKI was significantly better than the minimal model index of insulin sensitivity (SI(MM)) at predicting SI(Clamp) (CVPE = 1.54 vs. 1.98, P = 0.001). We conclude that QUICKI and log(HOMA) are among the most accurate surrogate indexes for determining insulin sensitivity in humans.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15983190     DOI: 10.2337/diabetes.54.7.1914

Source DB:  PubMed          Journal:  Diabetes        ISSN: 0012-1797            Impact factor:   9.461


  89 in total

1.  Complete correction of anemia by erythropoiesis-stimulating agents is associated with insulin resistance in hemodialysis patients.

Authors:  Gianni Biolo; Gianfranco Guarnieri; Rocco Barazzoni; Giovanni Panzetta
Journal:  Clin Exp Med       Date:  2010-11-16       Impact factor: 3.984

2.  High urinary sodium is associated with increased carotid intima-media thickness in normotensive overweight and obese adults.

Authors:  Jennifer N Njoroge; Samar R El Khoudary; Linda F Fried; Emma Barinas-Mitchell; Kim Sutton-Tyrrell
Journal:  Am J Hypertens       Date:  2010-05-27       Impact factor: 2.689

3.  Serum aldosterone is associated with inflammation and aortic stiffness in normotensive overweight and obese young adults.

Authors:  Jennifer N Cooper; Ping Tepper; Emma Barinas-Mitchell; Genevieve A Woodard; Kim Sutton-Tyrrell
Journal:  Clin Exp Hypertens       Date:  2011-10-18       Impact factor: 1.749

4.  Assessing the risk of impaired glucose metabolism in overweight adolescents in a clinical setting.

Authors:  P A Velasquez-Mieyer; P A Cowan; C P Neira; F Tylavsky
Journal:  J Nutr Health Aging       Date:  2008-12       Impact factor: 4.075

5.  Simple modeling allows prediction of steady-state glucose disposal rate from early data in hyperinsulinemic glucose clamps.

Authors:  Pooja Singal; Ranganath Muniyappa; Robin Chisholm; Gail Hall; Hui Chen; Michael J Quon; Kieren J Mather
Journal:  Am J Physiol Endocrinol Metab       Date:  2009-11-17       Impact factor: 4.310

6.  Systemic inflammation in childhood obesity: circulating inflammatory mediators and activated CD14++ monocytes.

Authors:  H S Schipper; R Nuboer; S Prop; H J van den Ham; F K de Boer; Ç Kesmir; I M H Mombers; K A van Bekkum; J Woudstra; J H Kieft; I E Hoefer; W de Jager; B Prakken; M van Summeren; E Kalkhoven
Journal:  Diabetologia       Date:  2012-07-18       Impact factor: 10.122

7.  [13C]glucose breath testing provides a noninvasive measure of insulin resistance: calibration analyses against clamp studies.

Authors:  Maysa Hussain; Morteza Jangorbhani; Sally Schuette; Robert V Considine; Robin L Chisholm; Kieren J Mather
Journal:  Diabetes Technol Ther       Date:  2013-10-11       Impact factor: 6.118

8.  Toll-like receptor 2 mediates high-fat diet-induced impairment of vasodilator actions of insulin.

Authors:  Hyun-Ju Jang; Hae-Suk Kim; Daniel H Hwang; Michael J Quon; Jeong-a Kim
Journal:  Am J Physiol Endocrinol Metab       Date:  2013-03-26       Impact factor: 4.310

9.  Effects of preoperative and intraoperative glucose administration on glucose use and fat catabolism during laparotomy under sevoflurane anesthesia in fasted rats.

Authors:  Yoshiteru Mori; Takayuki Kitamura; Gaku Kawamura; Kanako Sato; Rui Sato; Yuko Araki; Yoshitsugu Yamada
Journal:  J Physiol Sci       Date:  2015-08-18       Impact factor: 2.781

10.  High prevalence of abnormal glucose homeostasis secondary to decreased insulin secretion in individuals with hereditary haemochromatosis.

Authors:  D A McClain; D Abraham; J Rogers; R Brady; P Gault; R Ajioka; J P Kushner
Journal:  Diabetologia       Date:  2006-03-15       Impact factor: 10.122

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.