Literature DB >> 15982653

Coronal fractures of the distal femoral condyle: a biomechanical evaluation of four internal fixation constructs.

David J Hak1, James Nguyen, Shane Curtiss, Scott Hazelwood.   

Abstract

This study evaluated different fixation methods in posterior femoral condyle coronal fractures. A standardised osteotomy was created in synthetic composite femurs and fixed with one of four methods (one 3.5 mm diameter screw, two 3.5 mm screws, one 6.5 mm screw, two 6.5 mm screws). The stiffness and mean loads to specified displacements were measured. The stiffness of two 6.5 mm screws was significantly greater than both single 3.5 mm screw (3567 versus 2584N/mm; p=0.0075) and double 3.5 mm screws (3567 versus 2080N/mm; p=0.003). There was no statistical difference in the stiffness of one 6.5 mm screw compared to either the single or double 3.5mm screws. Increasing the screw diameter and using two screws increased the load at 1, 2 and 3 mm of displacement. In the fixation of posterior femoral condyle fractures, two 6.5 mm screws are more rigid than either single or double 3.5 mm screws. The use of a second screw marginally increases the rigidity of fixation. If 3.5 mm screws are used in the fixation of posterior femoral condyle fractures, at least two screws should be used to approximate the biomechanical stability of a single 6.5 mm screw.

Entities:  

Mesh:

Year:  2005        PMID: 15982653     DOI: 10.1016/j.injury.2005.02.013

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  12 in total

Review 1.  Coronal plane fracture of the femoral condyles: anatomy, injury patterns, and approach to management of the Hoffa fragment.

Authors:  Eric A White; George R Matcuk; Aaron Schein; Matt Skalski; Geoffrey S Marecek; Geoffrey S Maracek; Deborah M Forrester; Dakshesh B Patel
Journal:  Skeletal Radiol       Date:  2014-10-02       Impact factor: 2.199

2.  Reconstructive osteotomy for a malunited medial Hoffa fracture - A feasible salvage option.

Authors:  Binu Sasidharan; Surendra Shetty; Satheesh Philip; Shivanand Shetty
Journal:  J Orthop       Date:  2016-03-26

Review 3.  Coronal fractures of the medial femoral condyle: a series of 6 cases and review of literature.

Authors:  Mandeep Singh Dhillon; Aditya Krishna Mootha; Kamal Bali; Sharad Prabhakar; Sarvadeep Singh Dhatt; Vishal Kumar
Journal:  Musculoskelet Surg       Date:  2011-09-09

4.  A computed tomography-based classification of Hoffa fracture: Surgical treatment considerations and prognostic outcome with assessment of reproducibility.

Authors:  Rex Chandrabose; Sayantan Saha; Harish Kumar; Niraj Tapadiya; Bharath Hd
Journal:  J Orthop       Date:  2019-12-18

5.  A biomechanical comparison of two screw fixation methods in a Letenneur type I Hoffa fracture.

Authors:  Shu-Hsin Yao; Wei-Ren Su; Kai-Lan Hsu; Yueh Chen; Chih-Kai Hong; Fa-Chuan Kuan
Journal:  BMC Musculoskelet Disord       Date:  2020-07-28       Impact factor: 2.362

6.  Corrective Osteotomy for Coronal Plane Malunion of the Medial Femoral Condyle.

Authors:  Fırat Ozan; Kürşat Tuğrul Okur; Ömer Can Ünlü; Muhammed Melez; Kamil Yamak; Cemil Kayalı; Taşkın Altay
Journal:  Cureus       Date:  2018-08-28

7.  Hoffa fracture combined with rotational dislocation of the knee joint: A novel case report.

Authors:  Guanning Huang; Minglei Zhang; Youjia Zhang; Xukai Wang; Mingran Zhang; Guangyao Liu
Journal:  Medicine (Baltimore)       Date:  2021-04-09       Impact factor: 1.817

8.  Clinical experience with management of Hoffa fractures using headless compression screw and headed screw.

Authors:  Vineet Maheshwari; S L Sharma; Divyanshu Goyal; Parwez Qureshi; Zakir Hussain
Journal:  J Clin Orthop Trauma       Date:  2018-10-19

9.  Non -Union of Lateral Hoffa Fracture - A Case Report.

Authors:  Amit Supe; Shubham Atal; Neetin P Mahajan; Prasanna Kumar G S; Amey Sadar; Pranay Kondewar
Journal:  J Orthop Case Rep       Date:  2021-02

10.  Functional Outcome of Isolated Hoffa Fractures Treated with Cannulated Cancellous Screw.

Authors:  R Singh; R B Singh; M Mahendra
Journal:  Malays Orthop J       Date:  2017-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.