Literature DB >> 15981866

Three-dimensional representation of complex muscle architectures and geometries.

Silvia S Blemker1, Scott L Delp.   

Abstract

Almost all computer models of the musculoskeletal system represent muscle geometry using a series of line segments. This simplification (i) limits the ability of models to accurately represent the paths of muscles with complex geometry and (ii) assumes that moment arms are equivalent for all fibers within a muscle (or muscle compartment). The goal of this work was to develop and evaluate a new method for creating three-dimensional (3D) finite-element models that represent complex muscle geometry and the variation in moment arms across fibers within a muscle. We created 3D models of the psoas, iliacus, gluteus maximus, and gluteus medius muscles from magnetic resonance (MR) images. Peak fiber moment arms varied substantially among fibers within each muscle (e.g., for the psoas the peak fiber hip flexion moment arms varied from 2 to 3 cm, and for the gluteus maximus the peak fiber hip extension moment arms varied from 1 to 7 cm). Moment arms from the literature were generally within the range of fiber moment arms predicted by the 3D models. The models accurately predicted changes in muscle surface geometry over a 55 degrees range of hip flexion, as compared to changes in shape predicted from MR images (average errors between the model and measured surfaces were between 1.7 and 5.2 mm). This new framework for representing muscle will enhance the accuracy of computer models of the musculoskeletal system.

Entities:  

Mesh:

Year:  2005        PMID: 15981866     DOI: 10.1007/s10439-005-1433-7

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  60 in total

1.  A nonlinear model of passive muscle viscosity.

Authors:  G A Meyer; A D McCulloch; R L Lieber
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

2.  Differential segmental strain during active lengthening in a large biarticular thigh muscle during running.

Authors:  Jennifer A Carr; David J Ellerby; Richard L Marsh
Journal:  J Exp Biol       Date:  2011-10-15       Impact factor: 3.312

3.  Full-Body Musculoskeletal Model for Muscle-Driven Simulation of Human Gait.

Authors:  Apoorva Rajagopal; Christopher L Dembia; Matthew S DeMers; Denny D Delp; Jennifer L Hicks; Scott L Delp
Journal:  IEEE Trans Biomed Eng       Date:  2016-07-07       Impact factor: 4.538

4.  The influence of prior hamstring injury on lengthening muscle tissue mechanics.

Authors:  Amy Silder; Scott B Reeder; Darryl G Thelen
Journal:  J Biomech       Date:  2010-05-15       Impact factor: 2.712

5.  Effect of posture on hip angles and moments during gait.

Authors:  Cara L Lewis; Shirley A Sahrmann
Journal:  Man Ther       Date:  2014-09-06

6.  Is my model good enough? Best practices for verification and validation of musculoskeletal models and simulations of movement.

Authors:  Jennifer L Hicks; Thomas K Uchida; Ajay Seth; Apoorva Rajagopal; Scott L Delp
Journal:  J Biomech Eng       Date:  2015-01-26       Impact factor: 2.097

7.  Finite element model of the knee for investigation of injury mechanisms: development and validation.

Authors:  Ali Kiapour; Ata M Kiapour; Vikas Kaul; Carmen E Quatman; Samuel C Wordeman; Timothy E Hewett; Constantine K Demetropoulos; Vijay K Goel
Journal:  J Biomech Eng       Date:  2014-01       Impact factor: 2.097

8.  Characterization of three dimensional volumetric strain distribution during passive tension of the human tibialis anterior using Cine Phase Contrast MRI.

Authors:  Elisabeth R Jensen; Duane A Morrow; Joel P Felmlee; Naveen S Murthy; Kenton R Kaufman
Journal:  J Biomech       Date:  2016-09-15       Impact factor: 2.712

9.  Spatial variations in Achilles tendon shear wave speed.

Authors:  Ryan J DeWall; Laura C Slane; Kenneth S Lee; Darryl G Thelen
Journal:  J Biomech       Date:  2014-05-16       Impact factor: 2.712

10.  Measurement of tendon strain during muscle twitch contractions using ultrasound elastography.

Authors:  Joe Farron; Tomy Varghese; Darryl G Thelen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-01       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.