Literature DB >> 1598171

Use of penile prostheses to maintain external condom catheter drainage in spinal cord injury patients.

I Perkash1, J N Kabalin, S Lennon, V Wolfe.   

Abstract

This is a retrospective analysis of 79 spinal cord injury patients who have had penile implants from one to 14 years. The primary indication for implants was the loss of condom catheter with a small retractile penis. Mean period after injury to when the implants were placed was 8.24 years (range 1-21 years). Mean total length of time the implants have been followed was 7.08 years (1-14 years). Sixty patients responded to our detailed questionnaire and they have been subjected to further analysis: prior to the implant 46 patients (77%) frequently lost their condoms. Fourteen of the patients (23%) had indwelling catheters, and 3 (5%) had a suprapubic cystostomy since they could not retain an external condom for urinary drainage because of retraction of a small penis. Post implant, 81% of patients had no accidents involving condom loss, while 19% still lost condoms. All indwelling catheters could be removed except for one patient who continued with a suprapubic catheter following transurethral sphincterotomy (TURS) and a penile implant. Sixty-eight percent used the implant for sex and felt their wives were satisfied. Patient satisfaction survey showed a markedly increased self esteem, increased mobility without fear of condom loss, and an improved sex life. Overall, the long term prosthesis failure rate was 8%. The specific infection complication rate was less than 2%. The Flexirod semirigid, hinged prosthesis proved ideal in meeting the requirements for these patients.

Entities:  

Mesh:

Year:  1992        PMID: 1598171     DOI: 10.1038/sc.1992.76

Source DB:  PubMed          Journal:  Paraplegia        ISSN: 0031-1758


  4 in total

1.  Bladder management for adults with spinal cord injury: a clinical practice guideline for health-care providers.

Authors: 
Journal:  J Spinal Cord Med       Date:  2006       Impact factor: 1.985

2.  [A cylinder aneurysm of a penile prosthesis].

Authors:  J Pannek; P Bartel; K Göcking
Journal:  Urologe A       Date:  2011-07       Impact factor: 0.639

3.  Infection rate of penile prosthesis implants in men with spinal cord injury: a meta-analysis of available evidence.

Authors:  Daniele Tienforti; Maria Totaro; Luca Spagnolo; Francesca Di Giulio; Chiara Castellini; Giorgio Felzani; Marco Giorgio Baroni; Sandro Francavilla; Arcangelo Barbonetti
Journal:  Int J Impot Res       Date:  2022-10-18       Impact factor: 2.408

Review 4.  Treatment of erectile dysfunction following spinal cord injury.

Authors:  Todd A Linsenmeyer
Journal:  Curr Urol Rep       Date:  2009-11       Impact factor: 3.092

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.