Literature DB >> 15980232

Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma.

Catherine Boden1, John Pascual, Felipe A Medeiros, Makoto Aihara, Robert N Weinreb, Pamela A Sample.   

Abstract

PURPOSE: To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up.
METHODS: This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT.
RESULTS: More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r2= 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT.
CONCLUSIONS: Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up.

Entities:  

Mesh:

Year:  2005        PMID: 15980232     DOI: 10.1167/iovs.04-1108

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  6 in total

1.  Understanding disparities among diagnostic technologies in glaucoma.

Authors:  Carlos Gustavo V De Moraes; Jeffrey M Liebmann; Robert Ritch; Donald C Hood
Journal:  Arch Ophthalmol       Date:  2012-07

2.  Clinical use of multifocal visual-evoked potentials in a glaucoma practice: a prospective study.

Authors:  Carlos Gustavo De Moraes; Jeffrey M Liebmann; Robert Ritch; Donald C Hood
Journal:  Doc Ophthalmol       Date:  2012-04-05       Impact factor: 2.379

3.  Peripapillary fundus perimetry in eyes with glaucoma.

Authors:  E Convento; E Midena; M T Dorigo; V Maritan; F Cavarzeran; I A Fregona
Journal:  Br J Ophthalmol       Date:  2006-06-29       Impact factor: 4.638

4.  Arterial spin labeling fMRI measurements of decreased blood flow in primary visual cortex correlates with decreased visual function in human glaucoma.

Authors:  Robert O Duncan; Pamela A Sample; Christopher Bowd; Robert N Weinreb; Linda M Zangwill
Journal:  Vision Res       Date:  2012-03-29       Impact factor: 1.886

5.  Evaluation of the significance of some diagnostic parameters in making an early diagnose of primary open-angle glaucoma.

Authors:  Barbara Polaczek-Krupa; Iwona Grabska-Liberek
Journal:  Med Sci Monit       Date:  2012-07

6.  Use of macular thickness parameters for the diagnosis of primary open-angle glaucoma.

Authors:  Barbara Polaczek-Krupa; Iwona Grabska-Liberek; Michał Kamiński
Journal:  Arch Med Sci       Date:  2014-02-23       Impact factor: 3.318

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.