Literature DB >> 15979637

Comparison of electrochemiluminescence assay and ELISA for the detection of Clostridium botulinum type B neurotoxin.

V Guglielmo-Viret1, O Attrée, V Blanco-Gros, P Thullier.   

Abstract

We compared the ELISA and electrochemiluminescence (ECL) immunoassay technologies for the detection of botulinum type B neurotoxin (BotNT B), which requires highly sensitive techniques due to its potent biological activity. BotNT B complexes are the naturally secreted form of the toxin, approximately a third of which consists of the neurotoxin itself; they were aliquoted and frozen for this study. Results of both techniques were interpreted with the same standard statistical tests (ANOVA and Tukey). We first compared two commercial assays for BotNT B: the detection limit of the colorimetric ELISA was 1.56 ng/ml BotNT B complexes versus 0.39-0.78 ng/ml in the ECL test. We then used the same monoclonal antibody and the same polyclonal antibody, respectively purified by protein A and protein G chromatography, to optimize an in-house ELISA test and an in-house ECL test, making it possible to directly compare the two technologies without interference due to the properties of the antibodies used in the two tests. The colorimetric in-house ELISA had a detection threshold of 3.12 ng/ml versus the in-house ECL test whose detection threshold was 0.78-1.56 ng/ml. Thus, in both cases, the ECL assay was two to four times more sensitive than the colorimetric ELISA. The ECL assay was also more rapid (2.5 h for the in-house ECL versus 5 h for in-house ELISA with precoated wells). Overall, these elements can be used to compare the qualities of the two technologies, at least for the detection of protein antigens such as toxins.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15979637     DOI: 10.1016/j.jim.2005.04.003

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  17 in total

1.  A fluorescence detection platform using spatial electroluminescent excitation for measuring botulinum neurotoxin A activity.

Authors:  Kim E Sapsford; Steven Sun; Jesse Francis; Shashi Sharma; Yordan Kostov; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2008-06-18       Impact factor: 10.618

2.  Electrical percolation-based biosensor for real-time direct detection of staphylococcal enterotoxin B (SEB).

Authors:  Minghui Yang; Steven Sun; Hugh Alan Bruck; Yordan Kostov; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2010-04-21       Impact factor: 10.618

3.  Multi-wavelength Spatial LED illumination based detector for in vitro detection of Botulinum Neurotoxin A Activity.

Authors:  Steven Sun; Jesse Francis; Kim E Sapsford; Yordan Kostov; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2010-04-08       Impact factor: 7.460

Review 4.  Laboratory diagnostics of botulism.

Authors:  Miia Lindström; Hannu Korkeala
Journal:  Clin Microbiol Rev       Date:  2006-04       Impact factor: 26.132

5.  Carbon nanotubes with enhanced chemiluminescence immunoassay for CCD-based detection of Staphylococcal enterotoxin B in food.

Authors:  Minghui Yang; Yordan Kostov; Hugh A Bruck; Avraham Rasooly
Journal:  Anal Chem       Date:  2008-10-15       Impact factor: 6.986

6.  Synthesis, labeling and bioanalytical applications of a tris(2,2'-bipyridyl)ruthenium(II)-based electrochemiluminescence probe.

Authors:  Xiaoming Zhou; Debin Zhu; Yuhui Liao; Weipeng Liu; Hongxing Liu; Zhaokui Ma; Da Xing
Journal:  Nat Protoc       Date:  2014-04-17       Impact factor: 13.491

7.  Lab-on-a-chip for botulinum neurotoxin a (BoNT-A) activity analysis.

Authors:  Steven Sun; Miguel Ossandon; Yordan Kostov; Avraham Rasooly
Journal:  Lab Chip       Date:  2009-09-17       Impact factor: 6.799

8.  Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of botulinum neurotoxin using high-affinity antibodies.

Authors:  Marvin G Warner; Jay W Grate; Abby Tyler; Richard M Ozanich; Keith D Miller; Jianlong Lou; James D Marks; Cynthia J Bruckner-Lea
Journal:  Biosens Bioelectron       Date:  2009-06-26       Impact factor: 10.618

9.  Detection of botulinum neurotoxin serotypes A and B using a chemiluminescent versus electrochemiluminescent immunoassay in food and serum.

Authors:  Luisa W Cheng; Larry H Stanker
Journal:  J Agric Food Chem       Date:  2013-01-10       Impact factor: 5.279

10.  Antibodies against insulin measured by electrochemiluminescence predicts insulitis severity and disease onset in non-obese diabetic mice and can distinguish human type 1 diabetes status.

Authors:  Bernice Lo; Austin D E Swafford; Kimberly A Shafer-Weaver; Lawrence F Jerome; Luba Rakhlin; Douglas R Mathern; Conor A Callahan; Ping Jiang; Lucy J Davison; Helen E Stevens; Carrie L Lucas; Jill White; Reid von Borstel; John A Todd; Michael J Lenardo
Journal:  J Transl Med       Date:  2011-11-28       Impact factor: 5.531

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.