Literature DB >> 15977741

Effects of external pressure on arteries distal to the cuff during sphygmomanometry.

Meir Nitzan1, Chaim Rosenfeld, A Teddy Weiss, Ehud Grossman, Amikam Patron, Alan Murray.   

Abstract

The aim of this study was to examine the effect on distal arteries of external pressure, applied by upper arm sphygmomanometer cuff. Photoplethysmographic (PPG) signals were measured on the index fingers of 44 healthy male subjects, during the slow decrease of cuff air pressure. For each pulse the ratio of PPG amplitude to its baseline (AM/BL) and its time delay (deltaTD) relative to the contralateral hand were determined as a function of cuff pressure. At cuff pressures equal to systolic blood pressure, pulses reappeared with the pulse time delay in the cuffed arm significantly greater than in the noncuffed arm, with (deltaTD) (mean +/- SD) 150 +/- 31 ms (p < 0.001). At cuff pressures equal to diastolic blood pressure (81 +/- 12 mmHg), deltaTD was 42 +/- 19 ms (p < 0.001), and at 50 mmHg, which is below diastolic blood pressure, (deltaTD) was still significantly positive at 6 +/- 9 ms (p < 0.001). AM/BL relative to its initial value rose at cuff pressures between systolic and diastolic blood pressure, then deceased to 0.6 +/- 0.41 (p < 0.001) at diastolic blood pressure and 0.54 +/- 0.24 (p < 0.001) at 50 mmHg. The changes in (deltaTD) and AM/BL can be interpreted as originating from changes in the compliance of conduit arteries and small arteries with cuff inflation and deflation.

Mesh:

Year:  2005        PMID: 15977741     DOI: 10.1109/TBME.2005.846710

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  Automatic noninvasive measurement of systolic blood pressure using photoplethysmography.

Authors:  Meir Nitzan; Amikam Patron; Zehava Glik; Abraham T Weiss
Journal:  Biomed Eng Online       Date:  2009-10-26       Impact factor: 2.819

2.  Arteries Stiffen With Age, but Can Retain an Ability to Become More Elastic With Applied External Cuff Pressure.

Authors:  Chengyu Liu; Dingchang Zheng; Alan Murray
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

3.  Comparison of systolic blood pressure values obtained by photoplethysmography and by Korotkoff sounds.

Authors:  Meir Nitzan; Yair Adar; Ellie Hoffman; Eran Shalom; Shlomo Engelberg; Iddo Z Ben-Dov; Michael Bursztyn
Journal:  Sensors (Basel)       Date:  2013-10-31       Impact factor: 3.576

4.  More accurate systolic blood pressure measurement is required for improved hypertension management: a perspective.

Authors:  Meir Nitzan; Itzchak Slotki; Linda Shavit
Journal:  Med Devices (Auckl)       Date:  2017-07-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.