Literature DB >> 15976582

The effects of high-Dk rigid contact lens center thickness, material permeability, and blinking on the oxygen uptake of the human cornea.

Hope Patterson Gardner1, Barbara A Fink, Lynn G Mitchell, Richard M Hill.   

Abstract

PURPOSE: The human corneal oxygen uptake responses associated with the static (nonblinking) and dynamic (blinking) wear of five rigid gas-permeable materials with high oxygen permeabilities were determined for three different center thicknesses and compared with the responses for the normal open eye and severe hypoxic stress (static wear of polymethylmethacrylate).
METHODS: Corneal oxygen uptake rates were measured with a Clark-type polarographic electrode during two sessions with each of 10 human subjects. Measurements were made on the right eye for the normal open eye (air) and after 5 minutes of static and dynamic wear of polymethylmethacrylate and five rigid gas-permeable contact lens materials: Fluoroperm 92 (paflufocon A, Dk = 92), Fluoroperm 151 (paflufocon D, Dk = 151), 1992 Menicon SF-P (melafocon A, Dk = 102), 1995 Menicon SF-P (melafocon A, Dk = 159), and Menicon Z (tisilfocon A, Dk = 163-250). Lenses were manufactured in three different center thicknesses (0.12, 0.16, and 0.20 mm), with all other parameters remaining constant. Repeated-measures analysis of variance was used and included lens material (five levels), blinking condition (two levels), and lens thickness (three levels) as within-subject effects.
RESULTS: Significant differences were found in corneal oxygen responses to lens material (p < 0.001) and lens thickness (p < 0.001), with lenses of lower oxygen permeability and thicker lenses being associated with higher oxygen uptake. No statistically significant differences were noted between static or dynamic wear of the lens materials (p = 0.59).
CONCLUSIONS: For those very high Dk rigid lens materials studied here, moderate changes in lens thickness or material permeability may result in modest differences in corneal hypoxic relief, whereas blinking results in no significant improvement to corneal oxygenation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15976582     DOI: 10.1097/01.opx.0000168562.64251.66

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  3 in total

1.  Tear oxygen under hydrogel and silicone hydrogel contact lenses in humans.

Authors:  Joseph A Bonanno; Christopher Clark; John Pruitt; Larry Alvord
Journal:  Optom Vis Sci       Date:  2009-08       Impact factor: 1.973

2.  Comparison of Two Main Orthokeratology Lens Designs in Efficacy and Safety for Myopia Control.

Authors:  Weiwei Lu; Rui Ning; Kai Diao; Yang Ding; Ruru Chen; Lei Zhou; Yan Lian; Colm McAlinden; Francis W B Sanders; Fangfang Xia; Jinhai Huang; Wanqing Jin
Journal:  Front Med (Lausanne)       Date:  2022-04-01

Review 3.  The Safety of Orthokeratology--A Systematic Review.

Authors:  Yue M Liu; Peiying Xie
Journal:  Eye Contact Lens       Date:  2016-01       Impact factor: 2.018

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.