Literature DB >> 15975473

Reliability of a new correcting factor in calculating intraocular lens power after refractive corneal surgery.

Nicola Rosa1, Luigi Capasso, Michele Lanza, Gennarfrancesco Iaccarino, Antonio Romano.   

Abstract

PURPOSE: To test the reliability of a corneal radius correcting factor (R factor) in calculating intraocular lens (IOL) power in eyes that developed cataract after refractive surgery and compare it with the clinical history (CHM) and double-K (DKM) methods.
SETTING: Department of Ophthalmology, Second University of Naples, Naples, Italy.
METHODS: Nineteen eyes from the literature that underwent cataract extraction and IOL implantation after refractive surgery were used to compare actual postoperative and expected refractive errors utilizing the R factor, CHM, and DKM. Intraocular lens powers were calculated with 3 formulas: SRK/T, Hoffer Q and Holladay 1. The differences were evaluated with the Wilcoxon test and Spearman correlation.
RESULTS: With the R factor SRK/T and Holladay 1 formulas gave the best results; 16 (84.2%) and 17 (89.5%) eyes were within +/-2 diopters (D) of emmetropia. With CHM, the best results were obtained using the SRK/T and Holladay 1 formulas; with both formulas 12 (63.2%) eyes were within +/-2 D of emmetropia. With DKM, the best results were obtained using SRK/T and Holladay 1 formulas; with both formulas 10 eyes (52.63%) were in the range of +/-2 D from emmetropia.
CONCLUSIONS: The R factor can be used with the SRK/T or Holladay 1 formula because this method seems comparable or superior to DKM and CHM.

Entities:  

Mesh:

Year:  2005        PMID: 15975473     DOI: 10.1016/j.jcrs.2004.10.055

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  Challenges and approaches in modern biometry and IOL calculation.

Authors:  Wolfgang Haigis
Journal:  Saudi J Ophthalmol       Date:  2012-01

2.  Ray tracing software for intraocular lens power calculation after corneal excimer laser surgery.

Authors:  Megumi Saiki; Kazuno Negishi; Naoko Kato; Hidemasa Torii; Murat Dogru; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2014-02-25       Impact factor: 2.447

Review 3.  IOL power calculation after corneal refractive surgery.

Authors:  Maddalena De Bernardo; Luigi Capasso; Luisa Caliendo; Francesco Paolercio; Nicola Rosa
Journal:  Biomed Res Int       Date:  2014-07-21       Impact factor: 3.411

4.  Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach.

Authors:  Michele Lanza; Robert Koprowski; Mario Bifani Sconocchia
Journal:  Biomed Eng Online       Date:  2018-08-13       Impact factor: 2.819

  4 in total