Multidetector CT of the small bowel: evaluation after oral hyperhydration with isotonic solution.

S Mazzeo1, D Caramella, A Belcari, L Melai, C Cappelli, F Fontana, R Bertini, G Caproni, P Giusti, C Bartolozzi.   

Abstract

PURPOSE: The aim of our study was to assess the diagnostic capabilities of multidetector CT in the evaluation of the small bowel in different pathological conditions, with the use of oral hyperhydration with isotonic solution.
MATERIALS AND METHODS: The study retrospectively evaluated 106 patients who underwent multidetector CT of the small bowel. Four groups were considered on the basis of the clinical findings: group A (48 cases), with suspected or certain chronic inflammatory disease of the small bowel; group B (16 cases), with suspected neoplastic lesion of the small bowel; group C (17 cases), patients affected by malabsorption; group D (25 cases), others: 13 cases with non-specific abdominal pain, 4 cases with occult bleeding, 8 cases affected by fever of unknown origin. Thirteen patients had previously undergone surgical intestinal resection. In all cases the CT examination was performed after the oral administration of 2000 mL polyethylene glycol electrolyte balanced solution; before the scan, N-butyl scopolamine or glucagon were administered intravenously to obtain rapid inhibition of bowel peristalsis. All multidetector CT scans were acquired at baseline and 50 seconds after the I.V. administration of 110-130 ml high-concentration non-ionic iodinated contrast medium. The images were subsequently processed on a dedicated workstation (Advantage Windows 4.0, GE Medical Systems) to obtain multiplanar reconstruction (MPR). We considered the following CT findings: fold distribution, wall thickening and stratification and contrast enhancement, extraparietal involvement and abnormalities of the abdominal organs. The CT diagnoses were compared with the clinical and laboratory findings (86 cases) and with the results of barium follow-through (55 cases), ileo-colonoscopy (45 cases) or surgery (28 cases).
RESULTS: CT examination allowed the correct diagnosis in 86/106 cases (89%); 20 patients were not included in the study because of a poor (11 cases) or absent (9 cases) small bowel loop distension. The final diagnoses in the 86 patients were: Crohn's disease of the small bowel (38 cases), Crohn's disease of the duodenum (1 case), granulomatous colitis (3 cases), malabsorption (8 cases), neoplastic lesion (4 cases), post-radiation conglomeration of ileal loops (1 case), intestinal lymphangiectasia (1 case), ulceration of the last ileal loop (1 case). In 29 cases no abnormalities of the small bowel were found. Spiral CT yielded 52 true positive cases, 5 false negative cases, 2 false positive cases, and 27 true negative
RESULTS: The sensitivity of the technique was 91%, specificity 93% and diagnostic accuracy 92%.
CONCLUSIONS: Multidetector CT of the small bowel performed after oral hyperhydration with isosmotic solution, proved to be an accurate and thorough technique. It can be considered a safe and effective alternative to conventional radiographic studies and to small bowel spiral CT enema in patients that refuse the nasojejunal balloon catheter or the administration of methylcellulose.

Entities:  

Year:  2005        PMID: 15973225

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  11 in total

1.  New progress in CT and MRI examination and diagnosis of small intestinal tumors.

Authors:  Fei Miao; Ming-Liang Wang; Yong-Hua Tang
Journal:  World J Gastrointest Oncol       Date:  2010-05-15

2.  The role of capsule endoscopy after negative CT enterography in patients with obscure gastrointestinal bleeding.

Authors:  Hyun Mi Heo; Chan Hyuk Park; Joon Seok Lim; Jin Ha Lee; Bo Kyung Kim; Jae Hee Cheon; Tae Il Kim; Won Ho Kim; Sung Pil Hong
Journal:  Eur Radiol       Date:  2012-01-22       Impact factor: 5.315

3.  Multidetector CT in small-bowel neoplasms.

Authors:  L M Minordi; A Vecchioli; P Mirk; E Filigrana; G Poloni; L Bonomo
Journal:  Radiol Med       Date:  2007-10-21       Impact factor: 3.469

4.  Forty-slice MDCT enteroclysis: evaluation after oral administration of isotonic solution in Crohn's disease.

Authors:  G Lo Re; M Galia; T V Bartolotta; G Runza; A Taibbi; R Lagalla; M De Maria; M Midiri
Journal:  Radiol Med       Date:  2007-09-20       Impact factor: 3.469

5.  Advances in CT Imaging of GI Malignancies.

Authors:  Siva P Raman; Elliot K Fishman
Journal:  Gastrointest Cancer Res       Date:  2012-05

6.  Comparison between clinical and radiological evaluation before and after medical therapy in patients with Crohn's disease: new prospective roles of CT enterography.

Authors:  Laura Maria Minordi; Franco Scaldaferri; Luigi Larosa; Rosa Marra; Francesco Giordano; Lucrezia Laterza; Iolanda Scoleri; Andrea Poscia; Viviana Gerardi; Giovanni Bruno; Eleonora Gaetani; Antonio Gasbarrini; Amorino Vecchioli; Lorenzo Bonomo
Journal:  Radiol Med       Date:  2014-12-02       Impact factor: 3.469

7.  CT enteroclysis/enterography findings in drug-induced small-bowel damage.

Authors:  T Kishi; K Shimizu; S Hashimoto; H Onoda; Y Washida; I Sakaida; N Matsunaga
Journal:  Br J Radiol       Date:  2014-10-28       Impact factor: 3.039

Review 8.  Small bowel imaging in Crohn's disease.

Authors:  Helen Bungay
Journal:  Frontline Gastroenterol       Date:  2011-09-27

Review 9.  CT enterography: review of technique and practical tips.

Authors:  R Ilangovan; D Burling; A George; A Gupta; M Marshall; S A Taylor
Journal:  Br J Radiol       Date:  2012-05-02       Impact factor: 3.039

10.  Enteroclysis CT and PEG-CT in patients with previous small-bowel surgical resection for Crohn's disease: CT findings and correlation with endoscopy.

Authors:  Laura Maria Minordi; Amorino Vecchioli; Giuliana Poloni; Luisa Guidi; Italo De Vitis; Lorenzo Bonomo
Journal:  Eur Radiol       Date:  2009-05-05       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.