Literature DB >> 1597240

Estimation of organ input function and plasma clearance from the cardiac curve in dynamic scintigraphy.

J S Fleming1.   

Abstract

A theoretical description of the relationship between the count rate detected in the cardiac region of interest and the arterial organ input function in dynamic scintigraphy is presented. It is shown that, provided the time-activity curve for the heart is corrected for extra-cardiac and unlabelled activity, it is proportional to the arterial organ input over both the first-pass and equilibrium phases of the passage of an intravenously injected radiopharmaceutical. A practical example demonstrating the value and validity of correcting the cardiac curve in dynamic radio colloid scintigraphy is described. Estimates of the colloid clearance rate to reticuloendothelial sites using the cardiac curve without correction were significantly lower (mean 0.085/min) than those derived from the liver uptake curve (mean 0.213/min). However, corrected cardiac curve clearance rates (mean 0.225/min) were not significantly different from the liver ones. Also, the corrected cardiac curve clearance values correlated linearly with liver curve values (correlation coefficient 0.89, standard error of the estimate 0.021/min), whereas the uncorrected values showed no significant correlation. Thus, correction of the cardiac curve gave clearance rate values that were both more accurate and more precise than those obtained without correction.

Mesh:

Substances:

Year:  1992        PMID: 1597240     DOI: 10.1007/bf00175137

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  11 in total

1.  Deconvolution analysis of the scintillation camera renogram.

Authors:  R W Kenny; D M Ackery; J S Fleming; B A Goddard; R W Grant
Journal:  Br J Radiol       Date:  1975-06       Impact factor: 3.039

2.  Measurement of Hippuran plasma clearance using a gamma camera.

Authors:  J S Fleming
Journal:  Phys Med Biol       Date:  1977-05       Impact factor: 3.609

3.  Error analysis by simulation studies in renography deconvolution.

Authors:  R R Gullquist; J S Fleming
Journal:  Phys Med Biol       Date:  1987-03       Impact factor: 3.609

4.  A comprehensive analysis of renal DTPA studies. I. Theory and normal values.

Authors:  M D Rutland
Journal:  Nucl Med Commun       Date:  1985-01       Impact factor: 1.690

5.  Measurement of colloid clearance rate as an adjunct to static liver imaging.

Authors:  J Miller; B L Diffey; J S Fleming
Journal:  Eur J Nucl Med       Date:  1979-02-01

6.  Noninvasive measurement of blood flow and extraction fraction.

Authors:  A M Peters; R D Gunasekera; B L Henderson; J Brown; J P Lavender; M De Souza; J M Ash; D L Gilday
Journal:  Nucl Med Commun       Date:  1987-10       Impact factor: 1.690

7.  Extravascular chest wall technetium 99m diethylene triamine penta-acetic acid: implications for the measurement of renal function during renography.

Authors:  S D Bell; A M Peters
Journal:  Eur J Nucl Med       Date:  1991

8.  The 99mTc-DTPA dynamic renal scan with deconvolution analysis.

Authors:  B L Diffey; F M Hall; J R Corfield
Journal:  J Nucl Med       Date:  1976-05       Impact factor: 10.057

9.  In vivo measurement of liver perfusion in the normal and partially hepatectomized rat using Tc-99m sulfur colloid.

Authors:  S J Karran; C J Eagles; J S Fleming; D M Ackery
Journal:  J Nucl Med       Date:  1979-01       Impact factor: 10.057

10.  An association between parameters of liver blood flow and percentage hepatic replacement with tumour.

Authors:  T M Hunt; A D Flowerdew; A J Britten; J S Fleming; S J Karran; I Taylor
Journal:  Br J Cancer       Date:  1989-03       Impact factor: 7.640

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.