Literature DB >> 15972203

Glucose measurements with sensors and ultrasound.

Seungjun Lee1, Vivekanand Nayak, Jeff Dodds, Michael Pishko, Nadine Barrie Smith.   

Abstract

Accurate monitoring of the blood glucose level in diabetics is essential in preventing complications. Generally, conventional over-the-counter glucose meters require frequent painful finger punctures to obtain samples, which makes a noninvasive method preferable. The purpose of this study was to demonstrate that glucose levels can be measured transdermally with the combination of the low-profile cymbal array and an electrochemical glucose sensor consisting of amperometric electrodes and a novel glucose oxidase hydrogel. Interstitial fluid glucose concentrations can be determined with the electrochemical glucose sensor after the skin is made permeable to glucose by ultrasound (US) (20 kHz) with the thin (< 7 mm) and light (< 22 g) cymbal array. Using this array to deliver insulin into hyperglycemic rats, our previous experiments demonstrated that blood glucose levels would decrease 233.3 mg/dl with 5 min of US exposure. With the sensor and array, our goal was to determine the glucose levels of hyperglycemic rats noninvasively and evaluate the possible bioeffects. A total of 12 anesthetized rats were placed into two groups (US exposure group and control group) and the array (I(SPTP) = 100 mW/cm(2)) with a saline reservoir operating for 20 min was affixed to the abdomen. The array was removed and an electrochemical glucose sensor was placed on the exposed area to determine the glucose concentrations through the skin. Comparison was made using a commercial glucose meter with the blood collected from a jugular vein. The average blood glucose level determined by the sensor was 356.0 +/- 116.6 mg/dl, and the glucose level measured by the commercial glucose meter was 424.8 +/- 59.1 mg/dl. These results supported the use of this novel system consisting of the electrochemical glucose sensor and the cymbal array for glucose monitoring.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15972203     DOI: 10.1016/j.ultrasmedbio.2005.04.004

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  11 in total

1.  Fetal membrane transport enhancement using ultrasound for drug delivery and noninvasive detection.

Authors:  Lior Wolloch; Aharon Azagury; Riki Goldbart; Tamar Traitel; Gabriel Groisman; Mordechai Hallak; Joseph Kost
Journal:  Pharm Res       Date:  2014-07-31       Impact factor: 4.200

2.  Noninvasive ultrasonic glucose sensing with large pigs (approximately 200 pounds) using a lightweight cymbal transducer array and biosensors.

Authors:  Eun-Joo Park; Jacob Werner; Joshua Beebe; Samantha Chan; Nadine Barrie Smith
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

3.  Wearable flexible body matched electromagnetic sensors for personalized non-invasive glucose monitoring.

Authors:  Jessica Hanna; Youssef Tawk; Sami Azar; Ali H Ramadan; Batoul Dia; Elias Shamieh; Sumaya Zoghbi; Rouwaida Kanj; Joseph Costantine; Assaad A Eid
Journal:  Sci Rep       Date:  2022-09-01       Impact factor: 4.996

4.  Noninvasive transcutaneous sampling of glucose by electroporation.

Authors:  S Srinivasa Murthy; V Siva Ram Kiran; S K Mathur; S Narasimha Murthy
Journal:  J Diabetes Sci Technol       Date:  2008-03

5.  Passive Diffusion of Transdermal Glucose: Noninvasive Glucose Sensing Using a Fluorescent Glucose Binding Protein.

Authors:  Sunsanee Kanjananimmanont; Xudong Ge; KarunaSri Mupparapu; Govind Rao; Russell Potts; Leah Tolosa
Journal:  J Diabetes Sci Technol       Date:  2014-01-21

6.  Recent advances in noninvasive glucose monitoring.

Authors:  Chi-Fuk So; Kup-Sze Choi; Thomas Ks Wong; Joanne Wy Chung
Journal:  Med Devices (Auckl)       Date:  2012-06-29

Review 7.  Electrochemical Sensors for Clinic Analysis.

Authors:  You Wang; Hui Xu; Jianming Zhang; Guang Li
Journal:  Sensors (Basel)       Date:  2008-03-27       Impact factor: 3.576

Review 8.  Perspectives on transdermal ultrasound mediated drug delivery.

Authors:  Nadine Barrie Smith
Journal:  Int J Nanomedicine       Date:  2007

9.  Ultrasound mediated transdermal insulin delivery in pigs using a lightweight transducer.

Authors:  E J Park; Jacob Werner; Nadine Barrie Smith
Journal:  Pharm Res       Date:  2007-04-19       Impact factor: 4.580

10.  Dose comparison of ultrasonic transdermal insulin delivery to subcutaneous insulin injection.

Authors:  Eun-Joo Park; Jeff Dodds; Nadine Barrie Smith
Journal:  Int J Nanomedicine       Date:  2008
View more