Investigation of the effect of subcutaneous fat on image quality performance of 2D conventional imaging and tissue harmonic imaging.

Jacinta E Browne1, Amanda J Watson, Peter R Hoskins, Alex T Elliott.   

Abstract

Tissue harmonic imaging (THI) has been reported to improve contrast resolution, tissue differentiation and overall image quality in clinical examinations. However, a study carried out previously by the authors (Brown et al. 2004) found improvements only in spatial resolution and not in contrast resolution or anechoic target detection. This result may have been due to the homogeneity of the phantom. Biologic tissues are generally inhomogeneous and THI has been reported to improve image quality in the presence of large amounts of subcutaneous fat. The aims of the study were to simulate the distortion caused by subcutaneous fat to image quality and thus investigate further the improvements reported in anechoic target detection and contrast resolution performance with THI compared with 2D conventional imaging. In addition, the effect of three different types of fat-mimicking layer on image quality was examined. The abdominal transducer of two ultrasound scanners with 2D conventional imaging and THI were tested, the 4C1 (Aspen-Acuson, Siemens Co., CA, USA) and the C5-2 (ATL HDI 5000, ATL/Philips, Amsterdam, The Netherlands). An ex vivo subcutaneous pig fat layer was used to replicate beam distortion and phase aberration seen clinically in the presence of subcutaneous fat. Three different types of fat-mimicking layers (olive oil, lard and lard with fish oil capsules) were evaluated. The subcutaneous pig fat layer demonstrated an improvement in anechoic target detection with THI compared with 2D conventional imaging, but no improvement was demonstrated in contrast resolution performance; a similar result was found in a previous study conducted by this research group (Brown et al. 2004) while using this tissue-mimicking phantom without a fat layer. Similarly, while using the layers of olive oil, lard and lard with fish oil capsules, improvements due to THI were found in anechoic target detection but, again, no improvements were found for contrast resolution for any of the layer combinations. Therefore, it was felt that the lack of improvement in contrast resolution performance may be due to the test phantom design and not to whether a layer was present that caused beam distortion and phase aberrations.

Entities:  

Mesh:

Year:  2005        PMID: 15972201     DOI: 10.1016/j.ultrasmedbio.2005.03.012

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  Development of a training phantom for compression breast elastography-comparison of various elastography systems and numerical simulations.

Authors:  Kavitha Manickam; Machireddy Ramasubba Reddy; Suresh Seshadri; Bagyam Raghavan
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-17

2.  Mechanical and clinical performance of pulse-inversion tissue harmonic imaging in the superficial region.

Authors:  Chieko Sugawara; Akira Takahashi
Journal:  J Med Ultrason (2001)       Date:  2010-03-18       Impact factor: 1.314

3.  Statistical model of clutter suppression in tissue harmonic imaging.

Authors:  Xiang Yan; Mark F Hamilton
Journal:  J Acoust Soc Am       Date:  2011-03       Impact factor: 1.840

4.  Helping expectant mothers understand inadequate ultrasound images.

Authors:  Crispian Oates; Paula Taylor
Journal:  Ultrasound       Date:  2016-05-20

5.  Re: Helping expectant mothers understand inadequate ultrasound images.

Authors:  Stephen Wolstenhulme
Journal:  Ultrasound       Date:  2016-10-13

6.  Critical US visibility with tissue harmonic imaging of subcutaneous nodules().

Authors:  S M Stella; B Ciampi; D Melchiorre; E Benedetti; E Orsitto; P V Lippolis
Journal:  J Ultrasound       Date:  2011-06-29

7.  Efficacy of ultrasound-guided transversus abdominis plane block after laparoscopic bariatric surgery: a double blind, randomized, controlled study.

Authors:  Aparna Sinha; Lakshmi Jayaraman; Dinesh Punhani
Journal:  Obes Surg       Date:  2013-04       Impact factor: 4.129

8.  Image quality evaluation of ultrasound imaging systems: advanced B-modes.

Authors:  Elisabetta Sassaroli; Calum Crake; Andrea Scorza; Don-Soo Kim; Mi-Ae Park
Journal:  J Appl Clin Med Phys       Date:  2019-03       Impact factor: 2.102

9.  Pilot in vivo studies on transcutaneous boiling histotripsy in porcine liver and kidney.

Authors:  Tatiana D Khokhlova; George R Schade; Yak-Nam Wang; Sergey V Buravkov; Valeriy P Chernikov; Julianna C Simon; Frank Starr; Adam D Maxwell; Michael R Bailey; Wayne Kreider; Vera A Khokhlova
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.