Literature DB >> 15968674

In-plane velocity encoding with coherent steady-state imaging.

John Grinstead1, Shantanu Sinha.   

Abstract

Standard phase-contrast flow quantification (PC-FQ) using radiofrequency (RF) spoiled steady-state (SS) incoherent gradient-echo sequences have a relatively low signal-to-noise ratio (SNR). Unspoiled SS coherent (SSC) gradient-echo sequences have a higher intrinsic SNR and are T2/T1 weighted so that blood has a relatively large signal compared to other tissues. An SSC sequence that was modified to allow in-plane velocity encoding is presented. Velocity encoding was achieved by inverting the readout gradients. This offers the benefit that there is no resultant increase in repetition time (TR), which avoids increased sensitivity to off-resonance artifacts when conventional velocity-encoding methods using separate velocity-encoding gradients are extended to SSC sequences. The results of standard PC-FQ and the new method from in vitro experiments of constant and sinusoidal flow, and in vivo imaging of the carotid artery were compared. Vector field maps and paths obtained from particle-tracking calculations based on the velocity-encoded images were used to visualize the velocity data. The technique has the potential to increase the precision of PC-FQ measurements.

Entities:  

Mesh:

Year:  2005        PMID: 15968674     DOI: 10.1002/mrm.20526

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Pulse sequences for phase-contrast SSFP imaging from a single steady-state.

Authors:  J-F Nielsen; K S Nayak
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2006-05

2.  SSFP and GRE phase contrast imaging using a three-echo readout.

Authors:  Jon-Fredrik Nielsen; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

3.  Interleaved balanced SSFP imaging: artifact reduction using gradient waveform grouping.

Authors:  Jon-Fredrik Nielsen; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2009-03       Impact factor: 4.813

4.  Improving contrast to noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession.

Authors:  Jongho Lee; Masaki Fukunaga; Jeff H Duyn
Journal:  Neuroimage       Date:  2010-10-30       Impact factor: 6.556

5.  In vivo estimation and repeatability of force-length relationship and stiffness of the human achilles tendon using phase contrast MRI.

Authors:  Dongsuk Shin; Taija Finni; Sinyeob Ahn; John A Hodgson; Hae-Dong Lee; V Reggie Edgerton; Shantanu Sinha
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.