Literature DB >> 15967367

Direct electrochemical sensor for fast reagent-free DNA detection.

Elena Komarova1, Matt Aldissi, Anastasia Bogomolova.   

Abstract

A novel reagentless direct electrochemical DNA sensor has been developed using ultrathin films of the conducting polymer polypyrrole doped with an oligonucleotide probe. Our goal was to develop a prototype electrochemical DNA sensor for detection of a biowarfare pathogen, variola major virus. The sensor has been optimized for higher specificity and sensitivity. It was possible to detect 1.6 fmol of complementary oligonucleotide target in 0.1 ml in seconds by using chronoamperometry. The sensitivity of the developed sensor is comparable to indirect electrochemical DNA sensors, which use electrochemical labels and reagent-intensive amplification. The developed sensing electrode is reusable, highly stable and suitable for storage in solution or in dry state.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15967367     DOI: 10.1016/j.bios.2004.07.025

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

Review 1.  Evolution of nucleic acids biosensors detection limit III.

Authors:  Yuan Yuan Zhang; François-Xavier Guillon; Sophie Griveau; Fethi Bedioui; Mathieu Lazerges; Cyrine Slim
Journal:  Anal Bioanal Chem       Date:  2021-10-19       Impact factor: 4.142

Review 2.  Nanomaterials as analytical tools for genosensors.

Authors:  Khalid M Abu-Salah; Salman A Alrokyan; Muhammad Naziruddin Khan; Anees Ahmad Ansari
Journal:  Sensors (Basel)       Date:  2010-01-26       Impact factor: 3.576

3.  Electrochemical DNA hybridization sensors based on conducting polymers.

Authors:  Md Mahbubur Rahman; Xiao-Bo Li; Nasrin Siraj Lopa; Sang Jung Ahn; Jae-Joon Lee
Journal:  Sensors (Basel)       Date:  2015-02-05       Impact factor: 3.576

Review 4.  Over-the-Counter Biosensors: Past, Present, and Future.

Authors:  Thomas Ming-Hung Lee
Journal:  Sensors (Basel)       Date:  2008-09-06       Impact factor: 3.576

Review 5.  Progress in the Development of Intrinsically Conducting Polymer Composites as Biosensors.

Authors:  Deepak G Prajapati; Balasubramanian Kandasubramanian
Journal:  Macromol Chem Phys       Date:  2019-04-23       Impact factor: 2.527

6.  DNA-based bioanalytical microsystems for handheld device applications.

Authors:  Thomas Ming-Hung Lee; I-Ming Hsing
Journal:  Anal Chim Acta       Date:  2005-07-07       Impact factor: 6.558

Review 7.  The electrochemical detection of bioterrorism agents: a review of the detection, diagnostics, and implementation of sensors in biosafety programs for Class A bioweapons.

Authors:  Connor O'Brien; Kathleen Varty; Anna Ignaszak
Journal:  Microsyst Nanoeng       Date:  2021-02-10       Impact factor: 7.127

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.