John H Mullen1, Richard L Shugert, George D Ponsler, Qimin Li, Bhaskar Sundaram, Heather L Coales, Joseph E Yakupkovic, Richard M Lelacheur, William J Wheeler, Frank J Belas, John-Michael Sauer.
Abstract
A sensitive and selective liquid chromatography tandem mass spectrometry (LC/MS/MS) method for the determination of atomoxetine and its metabolites (4-hydroxyatomoxetine, N-des-methylatomoxetine, and 4-hydroxyatomoxetine-O-glucuronide) has been developed for human plasma and urine. Using stable-labeled internal standards, the method proved to be accurate and precise for the analytes in all species, resulting in inter-batch accuracy (percent relative error, %RE) within 100+/-13% and inter-batch precision (relative standard deviation, %RSD) within 11%. Stability was demonstrated for the analytes in neat solutions and the reconstitution solvent, as well as plasma and urine (with or without the deconjugation reagent). The method was simple, robust (utilized for the analysis of several hundred clinical study samples), and amenable to high sample throughput.Entities:
Mesh:
Substances:
Year: 2005 PMID: 15967301 DOI: 10.1016/j.jpba.2005.02.007
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935