In vitro determination of the optimal particle size for nebulized aerosol delivery to infants.

Karen G Schüepp1, Juergen Jauernig, Hettje M Janssens, Harm A W M Tiddens, Daniel A Straub, Roland Stangl, Manfred Keller, Johannes H Wildhaber.   

Abstract

We investigated the in vitro influence of breathing patterns on lung dose (LD) and particle size distribution in an infant upper airway cast model in order to determine the optimal particle size for nebulized aerosol delivery to infants. Budesol (nebulizer solution of budesonide) delivery from a perforated vibrating membrane nebulizer (eFlow Baby functional prototype) through an upper airway cast of a nine month old infant (SAINT-model) was measured at a fixed respiratory rate (RR) of 30 breaths per minute (bpm) and a tidal volume (Vt) of 50, 100, and 200 mL, respectively, and at a fixed Vt of 100 mL and a RR of 30, 60, and 78 bpm, respectively. LD expressed as a percentage of the nominal dose (ND; range, 5.8-30.3%) decreased with increasing Vt (p < 0.001) and with increasing RR (p < 0.001). Median mass aerodynamic diameter (MMAD) after passage (range, 2.4-3.4 microm) through the upper airway cast showed a negative correlation with increasing Vt (p < 0.001) and with increasing RR (p = 0.015). Particles available as LD for all simulated breathing pattern showed a particle size distribution with a MMAD of 2.4 microm and a geometric standard deviation (GSD) of 1.56. From our in vitro study, we conclude that the optimal particle size for nebulized aerosols for inhalation therapy for infants should have a MMAD of <2.4 microm.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15966777     DOI: 10.1089/jam.2005.18.225

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  7 in total

Review 1.  Challenges Associated with Route of Administration in Neonatal Drug Delivery.

Authors:  Matthew W Linakis; Jessica K Roberts; Anita C Lala; Michael G Spigarelli; Natalie J Medlicott; David M Reith; Robert M Ward; Catherine M T Sherwin
Journal:  Clin Pharmacokinet       Date:  2016-02       Impact factor: 6.447

2.  Jet nebulization of prostaglandin E1 during neonatal mechanical ventilation: stability, emitted dose and aerosol particle size.

Authors:  Beena G Sood; Jennifer Peterson; Monica Malian; Robert Galli; Maria Geisor-Walter; Jon McKinnon; Jody Sharp; Krishna Rao Maddipati
Journal:  Pharmacol Res       Date:  2007-10-02       Impact factor: 7.658

3.  Scientific respiratory symposium, paris june 2010.

Authors:  Gavin Dalglish; Graham Priestley
Journal:  J Asthma Allergy       Date:  2011-06-29

4.  Particle deposition in a child respiratory tract model: in vivo regional deposition of fine and ultrafine aerosols in baboons.

Authors:  Iolanda Albuquerque-Silva; Laurent Vecellio; Marc Durand; John Avet; Déborah Le Pennec; Michèle de Monte; Jérôme Montharu; Patrice Diot; Michèle Cottier; Francis Dubois; Jérémie Pourchez
Journal:  PLoS One       Date:  2014-04-30       Impact factor: 3.240

5.  Variability in delivered dose and respirable delivered dose from nebulizers: are current regulatory testing guidelines sufficient to produce meaningful information?

Authors:  Ross Hm Hatley; Sarah M Byrne
Journal:  Med Devices (Auckl)       Date:  2017-02-01

6.  Development of an ex vivo respiratory pediatric model of bronchopulmonary dysplasia for aerosol deposition studies.

Authors:  Yoann Montigaud; Sophie Périnel; Jean-Christophe Dubus; Lara Leclerc; Marie Suau; Clémence Goy; Anthony Clotagatide; Nathalie Prévôt; Jérémie Pourchez
Journal:  Sci Rep       Date:  2019-04-05       Impact factor: 4.379

7.  Initial Development of an Air-Jet Dry Powder Inhaler for Rapid Delivery of Pharmaceutical Aerosols to Infants.

Authors:  Connor Howe; Michael Hindle; Serena Bonasera; Vijaya Rani; P Worth Longest
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2020-08-04       Impact factor: 2.849

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.