Comparison of subtraction arthrography, radionuclide arthrography and conventional plain radiography to assess loosening of total knee arthroplasty.

Axel Marx1, Guido Saxler, Stefan Landgraeber, Franz Löer, Tim Holland-Letz, Marius von Knoch.   

Abstract

The value of plain radiographs, digital subtraction arthrography and radionuclide arthrography was analysed in 23 cases of failed total knee arthroplasty. The preoperative diagnosis was compared with the intraoperative assessment. Sensitivity, specificity and the positive and negative predictive value for assessing a loose component were determined separately for the femoral and tibial components. At revision we found 13 loose femoral and 12 loose tibial implants. In eight cases both components were unstable. Plain radiography had a sensitivity of 77% for loosening of the femoral and 83% for the tibial component; digital subtraction arthrography 77% for the femoral and 8% for the tibial component and radionuclide arthrography 31% and 8%. The specificity for plain radiography was 90% for the femoral and 72% for the tibial implant. For subtraction arthrography it was 50% and 82% and for subtraction arthrography 70% and 82%. Radiography had the highest positive and negative predictive values for both components compared with the other two techniques. As a diagnostic tool to detect implant loosening, plain radiography is the most effective in this study. Subtraction arthrography and radionuclide arthrography are not suitable for use as routine methods for detection of total knee arthroplasty loosening.

Entities:  

Mesh:

Year:  2005        PMID: 15966619     DOI: 10.1515/BMT.2005.021

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  3 in total

1.  The distribution of implant fixation for femoral components of TKA: a postmortem retrieval study.

Authors:  Karen I Howard; Mark A Miller; Timothy A Damron; Kenneth A Mann
Journal:  J Arthroplasty       Date:  2014-04-18       Impact factor: 4.757

2.  Peri-Implant Distribution of Polyethylene Debris in Postmortem-Retrieved Knee Arthroplasties: Can Polyethylene Debris Explain Loss of Cement-Bone Interlock in Successful Total Knee Arthroplasties?

Authors:  Karen I Cyndari; Jacklyn R Goodheart; Mark A Miller; Megan E Oest; Timothy A Damron; Kenneth A Mann
Journal:  J Arthroplasty       Date:  2017-02-03       Impact factor: 4.757

3.  Diagnostic algorithm in aseptic TKA failure - What is evidence-based?

Authors:  E Röhner; M Heinecke; G Matziolis
Journal:  J Orthop       Date:  2021-03-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.