Literature DB >> 15966054

Attempted cleaning of bloodstains and its effect on the forensic luminol test.

Jonathan I Creamer1, Terence I Quickenden, Leah B Crichton, Patrick Robertson, Rasha A Ruhayel.   

Abstract

The forensic luminol test has long been valued for its ability to detect trace amounts of blood that are invisible to the naked eye. This is the first quantitative study to determine the effect on the luminol test when an attempt is made to clean bloodstained tiles with a known interfering catalyst (bleach). Tiles covered with either wet or dry blood were tested, and either water or sodium hypochlorite solution (bleach) was used to clean the tiles. As expected, the chemiluminescence intensity produced when luminol was applied generally decreased with the number of times that a tile was cleaned with water, until the chemiluminescence was neither visible nor detectable. However, when the tiles were cleaned with bleach there was an initial drop in chemiluminescence intensity, followed by a rise to a consistently high value, visibly indistinguishable from that of blood. Examination of bleach drying time suggested that any interfering effect becomes negligible after 8 h. (c) 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15966054     DOI: 10.1002/bio.865

Source DB:  PubMed          Journal:  Luminescence        ISSN: 1522-7235            Impact factor:   2.464


  6 in total

1.  Blood stain pattern analysis.

Authors:  O Peschel; S N Kunz; M A Rothschild; E Mützel
Journal:  Forensic Sci Med Pathol       Date:  2010-11-11       Impact factor: 2.007

2.  Active oxygen doctors the evidence.

Authors:  Ana Castelló; Francesc Francès; Dolores Corella; Fernando Verdú
Journal:  Naturwissenschaften       Date:  2008-10-21

3.  Detectability, visualization, and DNA analysis of bloodstains after repainting the walls.

Authors:  Frank Ramsthaler; Julia Schlote; Axel Gehl; Sabine Cappel-Hoffmann; Mattias Kettner
Journal:  Int J Legal Med       Date:  2018-08-09       Impact factor: 2.686

Review 4.  Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses.

Authors:  Parvez Khan; Danish Idrees; Michael A Moxley; John A Corbett; Faizan Ahmad; Guido von Figura; William S Sly; Abdul Waheed; Md Imtaiyaz Hassan
Journal:  Appl Biochem Biotechnol       Date:  2014-04-22       Impact factor: 2.926

5.  Luminol chemiluminescence: contribution to postmortem interval determination of skeletonized remains in Portuguese forensic context.

Authors:  Catarina Ermida; David Navega; Eugénia Cunha
Journal:  Int J Legal Med       Date:  2017-01-30       Impact factor: 2.686

6.  Stable RNA markers for identification of blood and saliva stains revealed from whole genome expression analysis of time-wise degraded samples.

Authors:  Dmitry Zubakov; Eline Hanekamp; Mieke Kokshoorn; Wilfred van Ijcken; Manfred Kayser
Journal:  Int J Legal Med       Date:  2007-06-20       Impact factor: 2.686

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.