OBJECTIVE: To show, using a laboratory model, the inherent problems and test the validity of viewing actual pubis symphysis misalignment via plain film radiography in humans. STUDY
DESIGN: In vitro experiment of pubic bone and pubis symphysis model alignment as determined through projected imaging with collimated light.
RESULTS: The shadows cast by plastic models did not accurately reflect the physical reality. The image representations of the pubic bones with significant misalignment appeared as "normal." Some of the misalignments were viewed in the exact opposite alignment on the projected image as compared with the physical reality.
CONCLUSIONS: This study provides evidence that misalignment of the pubic bones cannot be reliably viewed on a standard anteroposterior lumbopelvic radiograph. The results show the potential for missed diagnoses of clinical significance. Additional research on pelvic joint dysfunction and imaging problems is needed.

Entities:  

Mesh:

Year:  2005        PMID: 15965407     DOI: 10.1016/j.jmpt.2005.04.015

Source DB:  PubMed          Journal:  J Manipulative Physiol Ther        ISSN: 0161-4754            Impact factor:   1.437


  2 in total

1.  Chiropractic management of pubic symphysis shear dysfunction in a patient with overactive bladder.

Authors:  Robert Cooperstein; Anthony Lisi; Andrew Burd
Journal:  J Chiropr Med       Date:  2014-06

2.  The Chiropractic Vertebral Subluxation Part 10: Integrative and Critical Literature From 1996 and 1997.

Authors:  Simon A Senzon
Journal:  J Chiropr Humanit       Date:  2019-04-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.