Literature DB >> 15964876

A case study: surface contamination of cyclophosphamide due to working practices and cleaning procedures in two Italian hospitals.

Antonio Acampora1, Loredana Castiglia, Nadia Miraglia, Maria Pieri, Claudio Soave, Francesco Liotti, Nicola Sannolo.   

Abstract

The efficacy of preventive and organisational measures implemented in Italy to prevent the contamination of cytotoxic drug preparation rooms has been investigated, and oncologic wards of two Italian hospitals were examined. The sampling strategy was based not only on potential sources of contamination but also on responses to detailed questionnaires on workplace practices and work organisation. Wipe samples were taken from different surfaces of preparation rooms, before and after the work shift, over a span of a month. Cyclophosphamide was taken as the marker drug that reflects exposure to cytotoxic drugs, being measurable by GC/MS. In one of the two hospitals (Hospital A), a large amount of cyclophosphamide was found, both before and after shift, on the workbench (median value, 2.55 microg dm(-2), before shift), on the floor between the operator working position and the waste bin (>10 microg dm(-2), after shift), as also on door handles and storage shelves. No quantifiable levels of cytotoxic drug were detected in the second hospital investigated (Hospital B). These results could be attributed to the efficacy of cleaning procedures and working practices. In fact, both hospitals were provided with vertical-laminar airflow hoods and the (male) nurses had attended special training courses; but in Hospital A, cleaning procedures were carried out without substances used specifically for the cleaning of surfaces contaminated by cytotoxic drugs such as sodium hypochlorite. Working practices did not include Luer Lock devices. Cyclophosphamide concentrations found in both hospitals, compared with the quantities of drug handled, gave evidence of the importance of the correct handling of cytotoxic agents as a major tool in reducing contamination levels. The results reveal the insufficiency of the risk management measures which do not take into account working practices that are prevailing, and stress the necessity for periodic environmental monitoring, indispensable for evolving effective procedures to prevent antineoplastic drug exposure.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15964876     DOI: 10.1093/annhyg/mei029

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  15 in total

1.  Effectiveness of cleaning of workplace cytotoxic surface.

Authors:  Laetitia Minh Mai Lê; Pierre Alain Jolivot; Hassane Sadou Yaye; André Rieutord; Agnès Bellanger; Dominique Pradeau; Séverine Barbault-Foucher; Eric Caudron
Journal:  Int Arch Occup Environ Health       Date:  2012-04-12       Impact factor: 3.015

2.  Evaluation of working practices and surface contamination with antineoplastic drugs in outpatient oncology health care settings.

Authors:  Bettina Kopp; Rudolf Schierl; Dennis Nowak
Journal:  Int Arch Occup Environ Health       Date:  2012-02-05       Impact factor: 3.015

3.  Hazardous drug residue on exterior vial surfaces: evaluation of a commercial manufacturing process.

Authors:  Luci A Power; Paul J M Sessink; Kathy Gesy; Flay Charbonneau
Journal:  Hosp Pharm       Date:  2014-04

4.  Reduction in surface contamination with antineoplastic drugs in 22 hospital pharmacies in the US following implementation of a closed-system drug transfer device.

Authors:  Paul J M Sessink; Thomas H Connor; James A Jorgenson; Timothy G Tyler
Journal:  J Oncol Pharm Pract       Date:  2010-02-15       Impact factor: 1.809

5.  Pilot Evaluation of Dermal Contamination by Antineoplastic Drugs among Hospital Pharmacy Personnel.

Authors:  Chun-Yip Hon; George Astrakianakis; Quinn Danyluk; Winnie Chu
Journal:  Can J Hosp Pharm       Date:  2011-09

6.  Antineoplastic drugs contamination of workplace surfaces in two Portuguese hospitals.

Authors:  Susana Viegas; Mário Pádua; Ana Costa Veiga; Elisabete Carolino; Mário Gomes
Journal:  Environ Monit Assess       Date:  2014-08-06       Impact factor: 2.513

7.  Reduction in Surface Contamination With Cyclophosphamide in 30 US Hospital Pharmacies Following Implementation of a Closed-System Drug Transfer Device.

Authors:  Paul J M Sessink; Jason Trahan; Joseph W Coyne
Journal:  Hosp Pharm       Date:  2013-03

8.  Environmental and biological monitoring of antineoplastic drugs in four workplaces in a Swedish hospital.

Authors:  M Hedmer; H Tinnerberg; A Axmon; B A G Jönsson
Journal:  Int Arch Occup Environ Health       Date:  2007-12-08       Impact factor: 3.015

9.  Evaluating Six Commercially Available Closed-System Drug-Transfer Devices Against NIOSH's 2015 Draft Vapor Protocol.

Authors:  Shiraz Halloush; Ivan A Reveles; Jim Koeller
Journal:  Hosp Pharm       Date:  2019-06-06

10.  Comparison of Decontamination Efficacy of Cleaning Solutions on a Biological Safety Cabinet Workbench Contaminated by Cyclophosphamide.

Authors:  Apolline Adé; Laure Chauchat; Johann-François Ouellette Frève; Sébastien Gagné; Nicolas Caron; Jean-François Bussières
Journal:  Can J Hosp Pharm       Date:  2017-12-21
View more