A respiration-metabolism chamber system and a GC-MS method developed for studying exhalation of perfluorobutane in rats after intravenous injection of the ultrasound contrast agent Sonazoid.

Steinar Uran1, Kristin Landmark, Per Trygve Normann, Petter-Arnt Hals, Kim Gunnar Toft, Tore Skotland.   

Abstract

Sonazoid is a new contrast agent for ultrasound imaging comprising an aqueous suspension of lipid-stabilised perfluorobutane (PFB) gas microbubbles. A respiration-metabolism chamber system was developed to collect exhaled air following intravenous administration of Sonazoid to rats. Analysis of PFB in the exhaled rat air was performed using a modified version of an earlier published method for blood samples, i.e. an automatic headspace gas chromatographic mass spectrometric (GC-MS) method using electron impact ionisation. The calibration standards were PFB diluted in air (2.5-1800 pg/ml). Perfluoropentane (PFP) was used as an internal standard and the MS detector was set to single ion monitoring of the base fragment ions of PFB (m/z 69 and 119) and PFP (m/z 69). The calibration curve, made by plotting the peak area ratios of PFB (m/z 69) to PFP (m/z 69) against the theoretical concentration of PFB, was fitted to a linear equation with weighting 1/y2 and found to be reproducible. The lower limit of quantification (LLOQ) was 2.5 pg PFB/ml. The between-day variation of the method was below 2.6% relative standard deviation (R.S.D.) and the within-day variation of the method was below 6.4% R.S.D. The accuracy of the method was evaluated and showed a relative error less than 5.2%. PFB was found to be stable for 14 days when stored in Tedlar sample bags at room temperature. An even lower detection limit may be obtained by using the more time-consuming process of solid-phase micro extraction; thus, by concentrating PFB on carboxen-PDMS fibres an LLOQ of 0.5 pg PFB/ml was obtained. When five rats were given an i.v. bolus injection of Sonazoid at a dose of 8 microl microbubbles/kg a mean recovery of 96% (range, 81-110%) was found during 24 h; more than 50% was exhaled during the first 30 min after injection.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15964732     DOI: 10.1016/j.jpba.2005.04.038

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Contrast-enhanced ultrasound for the evaluation of acute renal infarction.

Authors:  Toru Miyoshi; Hideki Okayama; Go Hiasa; Yoshitaka Kawata; Tadakatsu Yamada; Yukio Kazatani
Journal:  J Med Ultrason (2001)       Date:  2015-08-27       Impact factor: 1.314

2.  Contrast-enhanced endoscopic ultrasonography (CE-EUS) findings in adrenal metastasis from renal cell carcinoma.

Authors:  Susumu Hijioka; Akira Sawaki; Nobumasa Mizuno; Kazuo Hara; Mohamed A Mekky; Hussein El-Amin; Zain El-Abdeen Ahmed Sayed; Mssahiro Tajika; Yasumasa Niwa; Kenji Yamao
Journal:  J Med Ultrason (2001)       Date:  2011-01-05       Impact factor: 1.314

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.