Literature DB >> 15961844

The dose response of normoxic polymer gel dosimeters measured using X-ray CT.

B Hill1, A Venning, C Baldock.   

Abstract

X-ray CT was used to determine the dose response of normoxic polymer gel dosimeters. Normoxic polymer gel dosimeters were manufactured and irradiated up to 150 Gy. Up to 50 CT images were acquired on a Toshiba Aquilion Multislice CT scanner using protocols for 80 kV and 135 kV to determine dose response. HU-dose sensitivity, the linear regression of data for the HU versus dose for the linear part of the curve up to 60 Gy was 0.38+/-0.07 HU Gy(-1) for 135 kV and 0.37+/-0.01 HU Gy(-1) for 80 kV. Dose resolution was found to be < 1.3 Gy for an absorbed dose range up to 70 Gy for 135 kV, similar to that measured previously for polyacrylamide gel (PAG). Although the HU-dose sensitivity was lower than that previously measured for PAG gel dosimeters it had a greater range of absorbed dose indicating that normoxic polymer gel dosimeters have potential in CT gel dosimetry.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15961844     DOI: 10.1259/bjr/46029447

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  7 in total

Review 1.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

2.  Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry.

Authors:  Asghar Mesbahi; Vahid Jafarzadeh; Nahideh Gharehaghaji
Journal:  Rep Pract Oncol Radiother       Date:  2012-04-17

3.  Optimization of the imaging protocol of an X-ray CT scanner for evaluation of normoxic polymer gel dosimeters.

Authors:  Brindha Subramanian; Paul B Ravindran; Clive Baldock
Journal:  J Med Phys       Date:  2006-04

4.  Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on Dithiothreitol and Methacrylic Acid (MAGADIT): Sensitivity, Range, Reproducibility, Accuracy, Dose Rate Effect and Impact of Oxygen Scavenger.

Authors:  Muzafar Khan; Gerd Heilemann; Wolfgang Lechner; Dietmar Georg; Andreas Georg Berg
Journal:  Polymers (Basel)       Date:  2019-10-19       Impact factor: 4.329

Review 5.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

6.  A novel method of estimating dose responses for polymer gels using texture analysis of scanning electron microscopy images.

Authors:  Cheng-Ting Shih; Jui-Ting Hsu; Rou-Ping Han; Bor-Tsung Hsieh; Shu-Jun Chang; Jay Wu
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

7.  A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.

Authors:  Kai-Yuan Cheng; Ling-Ling Hsieh; Cheng-Ting Shih
Journal:  PLoS One       Date:  2016-05-18       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.