Literature DB >> 15961605

Effectiveness of mask and helmet interfaces to deliver noninvasive ventilation in a human model of resistive breathing.

Fabrizio Racca1, Lorenzo Appendini, Cesare Gregoretti, Elisa Stra, Antonio Patessio, Claudio F Donner, V Marco Ranieri.   

Abstract

The helmet, a transparent latex-free polyvinyl chloride cylinder linked by a metallic ring to a soft collar that seals the helmet around the neck, has been recently proposed as an effective alternative to conventional face mask to deliver pressure support ventilation (PSV) during noninvasive ventilation in patients with acute respiratory failure. We tested the hypothesis that mechanical characteristics of the helmet (large internal volume and high compliance) might impair patient-ventilator interactions compared with standard face mask. Breathing pattern, CO(2) clearance, indexes of inspiratory muscle effort and patient-ventilator asynchrony, and dyspnea were measured at different levels of PSV delivered by face mask and helmet in six healthy volunteers before (load-off) and after (load-on) application of a linear resistor. During load-off, no differences in breathing pattern and inspiratory muscle effort were found. During load-on, the use of helmet to deliver pressure support increased inspiratory muscle effort and patient-ventilator asynchrony, worsened CO(2) clearance, and increased dyspnea compared with standard face mask. Autocycled breaths accounted for 12 and 25% of the total minute ventilation and for 10 and 23% of the total inspiratory muscle effort during mask and helmet PSV, respectively. We conclude that PSV delivered by helmet interface is less effective in unloading inspiratory muscles compared with PSV delivered by standard face mask. Other ventilatory assist modes should be tested to exploit to the most the potential benefits offered by the helmet.

Entities:  

Mesh:

Year:  2005        PMID: 15961605     DOI: 10.1152/japplphysiol.01363.2004

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  23 in total

1.  Influence of ventilator settings on patient-ventilator synchrony during pressure support ventilation with different interfaces.

Authors:  R Costa; P Navalesi; G Spinazzola; G Ferrone; A Pellegrini; F Cavaliere; R Proietti; M Antonelli; G Conti
Journal:  Intensive Care Med       Date:  2010-05-26       Impact factor: 17.440

2.  Comparative evaluation of different helmets on patient-ventilator interaction during noninvasive ventilation.

Authors:  R Costa; P Navalesi; G Spinazzola; M Rossi; F Cavaliere; M Antonelli; R Proietti; G Conti
Journal:  Intensive Care Med       Date:  2008-03-05       Impact factor: 17.440

3.  Neural trigger and cycling off during helmet pressure support ventilation: the epitome of the perfect patient ventilator interaction?

Authors:  Frédéric Vargas
Journal:  Intensive Care Med       Date:  2008-05-30       Impact factor: 17.440

4.  Noninvasive ventilatory management of the acute respiratory distress syndrome: a new era or just another tease!

Authors:  Robert M Kacmarek; Jesús Villar
Journal:  Ann Transl Med       Date:  2016-09

5.  Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

Authors:  Shinya Oda; Kei Otaki; Nozomi Yashima; Misato Kurota; Sachiko Matsushita; Airi Kumasaka; Hutaba Kurihara; Kaneyuki Kawamae
Journal:  J Anesth       Date:  2016-04-09       Impact factor: 2.078

6.  Non-invasive ventilation in chronic obstructive pulmonary disease patients: helmet versus facial mask.

Authors:  Paolo Navalesi; Roberta Costa; Piero Ceriana; Annalisa Carlucci; George Prinianakis; Massimo Antonelli; Giorgio Conti; Stefano Nava
Journal:  Intensive Care Med       Date:  2006-10-13       Impact factor: 17.440

7.  Helmet ventilation and carbon dioxide rebreathing: effects of adding a leak at the helmet ports.

Authors:  Fabrizio Racca; Lorenzo Appendini; Cesare Gregoretti; Ilaria Varese; Giacomo Berta; Ferdinando Vittone; Gabriela Ferreyra; Elisa Stra; V Marco Ranieri
Journal:  Intensive Care Med       Date:  2008-05-06       Impact factor: 17.440

8.  Facial skin breakdown in patients with non-invasive ventilation devices: report of two cases and indications for treatment and prevention.

Authors:  Michele Maruccia; Martina Ruggieri; Maria G Onesti
Journal:  Int Wound J       Date:  2013-07-22       Impact factor: 3.315

9.  Carbon dioxide rebreathing during non-invasive ventilation delivered by helmet: a bench study.

Authors:  Francesco Mojoli; Giorgio A Iotti; Maddalena Gerletti; Carlo Lucarini; Antonio Braschi
Journal:  Intensive Care Med       Date:  2008-04-18       Impact factor: 17.440

10.  High flow biphasic positive airway pressure by helmet--effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure.

Authors:  Onnen Moerer; Peter Herrmann; José Hinz; Paolo Severgnini; Edoardo Calderini; Michael Quintel; Paolo Pelosi
Journal:  Crit Care       Date:  2009-06-05       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.