Literature DB >> 15959938

A method to track cortical surface deformations using a laser range scanner.

Tuhin K Sinha1, Benoit M Dawant, Valerie Duay, David M Cash, Robert J Weil, Reid C Thompson, Kyle D Weaver, Michael I Miga.   

Abstract

This paper reports a novel method to track brain shift using a laser-range scanner (LRS) and nonrigid registration techniques. The LRS used in this paper is capable of generating textured point-clouds describing the surface geometry/intensity pattern of the brain as presented during cranial surgery. Using serial LRS acquisitions of the brain's surface and two-dimensional (2-D) nonrigid image registration, we developed a method to track surface motion during neurosurgical procedures. A series of experiments devised to evaluate the performance of the developed shift-tracking protocol are reported. In a controlled, quantitative phantom experiment, the results demonstrate that the surface shift-tracking protocol is capable of resolving shift to an accuracy of approximately 1.6 mm given initial shifts on the order of 15 mm. Furthermore, in a preliminary in vivo case using the tracked LRS and an independent optical measurement system, the automatic protocol was able to reconstruct 50% of the brain shift with an accuracy of 3.7 mm while the manual measurement was able to reconstruct 77% with an accuracy of 2.1 mm. The results suggest that a LRS is an effective tool for tracking brain surface shift during neurosurgery.

Entities:  

Mesh:

Year:  2005        PMID: 15959938      PMCID: PMC3839049          DOI: 10.1109/TMI.2005.848373

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  23 in total

1.  Registration of 3-D intraoperative MR images of the brain using a finite-element biomechanical model.

Authors:  M Ferrant; A Nabavi; B Macq; F A Jolesz; R Kikinis; S K Warfield
Journal:  IEEE Trans Med Imaging       Date:  2001-12       Impact factor: 10.048

2.  Measurement and analysis of brain deformation during neurosurgery.

Authors:  T Hartkens; D L G Hill; A D Castellano-Smith; D J Hawkes; C R Maurer; A J Martin; W A Hall; H Liu; C L Truwit
Journal:  IEEE Trans Med Imaging       Date:  2003-01       Impact factor: 10.048

3.  The adaptive bases algorithm for intensity-based nonrigid image registration.

Authors:  Gustavo K Rohde; Akram Aldroubi; Benoit M Dawant
Journal:  IEEE Trans Med Imaging       Date:  2003-11       Impact factor: 10.048

4.  A unified non-rigid feature registration method for brain mapping.

Authors:  Haili Chui; Lawrence Win; Robert Schultz; James S Duncan; Anand Rangarajan
Journal:  Med Image Anal       Date:  2003-06       Impact factor: 8.545

5.  Cortical surface registration for image-guided neurosurgery using laser-range scanning.

Authors:  Michael I Miga; Tuhin K Sinha; David M Cash; Robert L Galloway; Robert J Weil
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

6.  Model-driven brain shift compensation.

Authors:  Oskar Skrinjar; Arya Nabavi; James Duncan
Journal:  Med Image Anal       Date:  2002-12       Impact factor: 8.545

7.  Intraoperative compensation for brain shift.

Authors:  C Nimsky; O Ganslandt; P Hastreiter; R Fahlbusch
Journal:  Surg Neurol       Date:  2001-12

8.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

9.  Using serial imaging data to model variabilities in organ position and shape during radiotherapy.

Authors:  E Fontenla; C A Pelizzari; J C Roeske; G T Chen
Journal:  Phys Med Biol       Date:  2001-09       Impact factor: 3.609

10.  Error assessment during "image guided" and "imaging interactive" stereotactic surgery.

Authors:  H J Nauta
Journal:  Comput Med Imaging Graph       Date:  1994 Jul-Aug       Impact factor: 4.790

View more
  35 in total

1.  Design and evaluation of an optically-tracked single-CCD laser range scanner.

Authors:  Thomas S Pheiffer; Amber L Simpson; Brian Lennon; Reid C Thompson; Michael I Miga
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  A clinically applicable laser-based image-guided system for laparoscopic liver procedures.

Authors:  Matteo Fusaglia; Hanspeter Hess; Marius Schwalbe; Matthias Peterhans; Pascale Tinguely; Stefan Weber; Huanxiang Lu
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-17       Impact factor: 2.924

3.  Superficial vessel reconstruction with a multiview camera system.

Authors:  Filipe M M Marreiros; Sandro Rossitti; Per M Karlsson; Chunliang Wang; Torbjörn Gustafsson; Per Carleberg; Örjan Smedby
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-05

4.  An atlas-based method to compensate for brain shift: preliminary results.

Authors:  Prashanth Dumpuri; Reid C Thompson; Benoit M Dawant; A Cao; Michael I Miga
Journal:  Med Image Anal       Date:  2007-03-01       Impact factor: 8.545

5.  Intraoperative brain shift compensation: accounting for dural septa.

Authors:  Ishita Chen; Aaron M Coffey; Siyi Ding; Prashanth Dumpuri; Benoit M Dawant; Reid C Thompson; Michael I Miga
Journal:  IEEE Trans Biomed Eng       Date:  2010-11-22       Impact factor: 4.538

6.  Concepts and preliminary data toward the realization of image-guided liver surgery.

Authors:  David M Cash; Michael I Miga; Sean C Glasgow; Benoit M Dawant; Logan W Clements; Zhujiang Cao; Robert L Galloway; William C Chapman
Journal:  J Gastrointest Surg       Date:  2007-07       Impact factor: 3.452

7.  Robust surface registration using salient anatomical features for image-guided liver surgery: algorithm and validation.

Authors:  Logan W Clements; William C Chapman; Benoit M Dawant; Robert L Galloway; Michael I Miga
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

8.  Laser range scanning for image-guided neurosurgery: investigation of image-to-physical space registrations.

Authors:  Aize Cao; R C Thompson; P Dumpuri; B M Dawant; R L Galloway; S Ding; M I Miga
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

9.  A method for the assessment of time-varying brain shift during navigated epilepsy surgery.

Authors:  E De Momi; G Ferrigno; G Bosoni; P Bassanini; P Blasi; G Casaceli; D Fuschillo; L Castana; M Cossu; G Lo Russo; F Cardinale
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-07-17       Impact factor: 2.924

10.  Near Real-Time Computer Assisted Surgery for Brain Shift Correction Using Biomechanical Models.

Authors:  Kay Sun; Thomas S Pheiffer; Amber L Simpson; Jared A Weis; Reid C Thompson; Michael I Miga
Journal:  IEEE J Transl Eng Health Med       Date:  2014-04-30       Impact factor: 3.316

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.