Literature DB >> 15959892

Stable hybridoma cultivation in a pilot-scale acoustic perfusion system: long-term process performance and effect of recirculation rate.

Marcella C F Dalm1, Menno Jansen, Timo M P Keijzer, Wout M J van Grunsven, Arthur Oudshoorn, Johannes Tramper, Dirk E Martens.   

Abstract

Perfusion systems have the possibility to be operated continuously for several months. It is important that the performance of the cell retention device does not limit the operation time of a perfusion process used in the production of active pharmaceutical ingredients. Therefore, the aim of this study was to investigate the reliability and long-term stability of an acoustic perfusion process using the 200 L/d BioSep. As the BioSep is an external device, it is possible that dependent on the recirculation rate nutrient gradients occur in the external loop, which could affect the cell metabolism. Therefore, the effect of possible nutrient gradients on cell metabolism, viability and productivity was studied by varying the recirculation rate. In this study, it is shown that a perfusion process using a pilot-scale acoustic cell-retention device (200 L/d) is reliable and simple to operate, resulting in a stable 75-day cultivation of a hybridoma cell line producing a monoclonal antibody. The recirculation rate had a significant effect on the oxygen concentration in the external loop, with oxygen being depleted within the cell-retention device at recirculation rates below 6 m3/m(reactor)3.d (=600 L/d). The oxygen depletion at low circulation rates correlated with a slightly increased lactate production rate. For all other parameters no effect of the recirculation rate was observed, including cell death measured through the release of lactate dehydrogenase and specific productivity. A maximum specific productivity of 12 pg/cell.d was reached. Copyright 2005 Wiley Periodicals, Inc

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15959892     DOI: 10.1002/bit.20552

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  3 in total

Review 1.  Living with heterogeneities in bioreactors: understanding the effects of environmental gradients on cells.

Authors:  Alvaro R Lara; Enrique Galindo; Octavio T Ramírez; Laura A Palomares
Journal:  Mol Biotechnol       Date:  2006-11       Impact factor: 2.695

2.  Quantification of the dynamics of population heterogeneities in CHO cultures with stably integrated fluorescent markers.

Authors:  Johannes Möller; Marcel Rosenberg; Kristoffer Riecken; Ralf Pörtner; An-Ping Zeng; Uwe Jandt
Journal:  Anal Bioanal Chem       Date:  2020-03-04       Impact factor: 4.142

3.  Performance of an acoustic settler versus a hollow fiber-based ATF technology for influenza virus production in perfusion.

Authors:  Gwendal Gränicher; Juliana Coronel; Felix Trampler; Ingo Jordan; Yvonne Genzel; Udo Reichl
Journal:  Appl Microbiol Biotechnol       Date:  2020-04-15       Impact factor: 4.813

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.