Literature DB >> 15955182

Characteristics associated with low treatment satisfaction in patients with implanted cardioverter defibrillators: results from the LICAD study.

Karl-Heinz Ladwig1, Isabelle Deisenhofer, Heidi Simon, Claus Schmitt, Jens J Baumert.   

Abstract

The evaluation of low treatment satisfaction (LTS) with an implanted cardioverter defibrillator (ICD) remains a neglected area of clinical research. However, a trustful attitude toward an ICD is crucial. Within the scope of ICD health technology assessment, we searched for predictors of LTS. Of 195 ICD patients enrolled (mean 59.8 years, standard deviation 12.6), 163 (83.6%) were men and 26 (16.4%) were women. We measured anxiety, helplessness, and depression with standardized instruments and LTS with 11 dichotomous items concerning a mistrustful attitude, a negative body image, and low appraisal. A total of 47 (24.1%) patients were considered as LTS patients. Multivariate logistic regression was used for assessment of LTS. Adjusted for age and survey, LTS was significantly more prevalent in depressed, anxious, and phobic patients. Multivariate logistic regression including medical and psychological covariates revealed the experience of > or =5 shocks with an odds ratio (OR) of 10.17 (95% CI 3.57-29.00, P < or = 0.001), being employed with an OR of 8.07 (95% CI 2.39-27.19, P < or = 0.001), and feelings of helplessness (OR 4.61, 95% CI 1.79-11.90, P < or = 0.002) as the most important predictors for LTS. Women had a slightly not significant effect on LTS. Age, educational status, and depression were not significant. LTS patients required more support for living with the ICD (P < or = 0.001). Thus, LTS serves as surrogate measure for deteriorated psychic health. Clinicians should be advised to identify LTS patients and to consider psychotherapeutic counseling for them.

Entities:  

Mesh:

Year:  2005        PMID: 15955182     DOI: 10.1111/j.1540-8159.2005.09509.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  [Optimisation of subcutaneous defibrillator programming after inappropriate shocks due to new onset of right bundle branch block].

Authors:  Claudia Schaarschmidt; Christof Kolb
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-12

2.  [Inappropriate ICD therapies: All problems solved with MADIT-RIT?].

Authors:  Christof Kolb
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-04-21

3.  Association between symptoms of depression and anxiety with heart rate variability in patients with implantable cardioverter defibrillators.

Authors:  Jennifer L Francis; Ali A Weinstein; David S Krantz; Mark C Haigney; Phyllis K Stein; Peter H Stone; John S Gottdiener; Willem J Kop
Journal:  Psychosom Med       Date:  2009-08-06       Impact factor: 4.312

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.